Rapid, precise and energy-saving temperature changes in the range from -42 ºC to +190 ºC, along with fast humidity recovery times, make the TTC temperature test chamber and the CTC climatic test chamber with humidity unit a perfect duo for controlled material testing, function tests, ageing tests or climate tests on composites, concrete, plastics or electronic components in material technology, the automotive and aerospace industries, and electronics.
- Temperature range -42 °C to +190 °C
- Compact size (256 l)
- State-of-the-art control technology based on the Perfect performance class
- Electronically controlled active humidification and dehumidification from 10% to 98% rh
- Specifically suited for tests in accordance with DIN EN 60068-2-1, 2-2, 2-3 and 2-30
- High-tech insulation system for permanent insulation capacity and energy efficiency
- Average temperature change speed in heating operation: 10 K/min
- Average temperature change speed in cooling operation from +190°C to 0°C: 6 K/min
- Average temperature change speed in cooling operation according to IEC 60068-3-5: 4 K/min
- Chlorine-free, ozone-neutral refrigerant R 404 A
The climatic test chamber CTC and temperature test chamber TTC are, with a rated power of 7000 Watts, extremely powerful due to the optimally coordinated heating and cooling technology. Largest possible energy efficiency and reduction in noise had been two criteria for the Memmert engineers to fulfill. With a chamber volume of 256 litres, they provide plenty of space to offer, yet have a low floor space requirement because of their narrow and compact construction. In addition, the appliances can be conveniently moved on castors through any standard laboratory doors.
60 years of permanent development work, as well as numerous amounts of feedback from practical experience, are embodied in each of our appliances:
- The modular manufacturing concept in accordance with the principle of equal parts enables a highly varied and cost-effective production
- Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
- Heating concept adapted to the specific product for a precise and homogenous temperature control independent of chamber volume and load
- A wide range of options for programming and documentation using interfaces, Celsius software, integrated log memory and chip cards (features dependent on the controller class)
- Three-year guarantee for appliances except wear and tear parts
- The temperature values of all climatic test chambers are measured according to DIN 12880:2007-05 and DIN IEC 60068-3-5
- Each climatic test chamber is safety-tested and bears this sign:
Quality assurance in the humidity chamber
Due to the almost unlimited programming possibilities of temperature control profiles, the Memmert humidity chamber HCP provides the ideal conditions for material testing and environment simulation.
Special solutions my AtmoSAFE
For all of our standard products we can offer you pass-through appliances, customised temperature ranges, gas concentrations or air change, and many other special solutions.
Application Material research
Constant climate chamber HPP demonstrate the behaviour of paper and humidity.
Application Material research
The constant climate chamber shows that humidity has an effect on source materials and intermediate products during the manufacture of hard metal.