How to find your order number:

e.g. INC 153 E7(2) H5
Basic appliance code + Accessories code in any order plus quantity (x) required

Model sizes 108153246
Comfort module: two gas connections with quick release connectors, automatic switch-over of gas cylinders T1 T1 T1
Hygiene module: electropolished interior seamlessly welded by laser T2 T2 T2
Communication module: USB interface, "Celsius" standard software for programming and logging, ring log memory, printer interface T3 T3 T3
CO2 module: extended CO2 range from 0 to 20% T4 T4 T4
Premium module: includes Comfort, Hygiene, Communication and CO2 module T5 T5 T5
Humidity-Modul: active microprocessor control for humidifying and dehumidifying (40-97% rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation; humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile filter; (standard humidity limit control and water dishes are omitted). Can only be ordered together with new incubator (no retrofitting possible) K7 K7 K7
Entry port in the rear, heated, with silicone stopper, 57 mm inner diameter F9 F9 F9
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. H8(x) H8(x) H8(x)
HEPA-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit H9 H9 H9
4-part partitioning of interior with 4-part gas baffle (replacement of 3 full-width by 6 half-width shelves) - - K4
Locking door (security lock) B6 B6 B6
Door-hinges on left side B8 B8 B8
Extra perforated stainless steel shelf, half width - - E6(x)
Extra perforated stainless steel shelf, full width E7(x) E7(x) E7(x)
Additional stainless steel grid, full width E3(x) E3(x) E3(x)
Extra water dish, full width E2(x) E2(x) -
Extra water dish, half width - - E2(x)
Stacking version for 2 ovens of equal size (bottom oven modification) G3 G3 G3
Subframe 622 mm high G5 G5 G5
Subframe (130 mm high for two stacked cabinets) G7 G7 G7
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!) V9 V9 V9
Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties V1 V1 V1
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB V2 V2 V2
RS232 interface instead of USB W6 W6 W6
Interface Ethernet instead of USB inclusive software "Celsius Ethernet-Edition" W4 W4 W4
Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. W1 W1 W1
Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit W2 W2 W2
USB connection cable for computer interface W7 W7 W7
Connection cable for computer interface RS232 according to DIN 12 900-1 V6 V6 V6
Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and CO2 is reached) H5 H5 H5
Potential-free contact (24V/2A) with socket, 3-pin, according to NAMUR NE 28, for combined fault message of temperature and CO2 controller (e.g. supply failure, sensor fault, fuse) H6 H6 H6
Pressure reducing valve to DIN 8546, incl. gas cylinder monitor H7 H7 H7
Works calibration certificate for 5%, 7% and 10% CO2 (measured at 37 °C) Z5 Z5 Z5
IQ check list with works test data for oven as support for validation by customer Q1 Q1 Q1
OQ check list including one free-selectable CO2-, humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 with works test data as support for validation by customer Q2 Q2 Q2
Software conforming to FDA "Celsius FDA-Edition" for up to 16 units - only with Communication or Premium module Q3 Q3 Q3
Integration of additional units (up to max.16 units) into an already existent FDA-software licence Q4 Q4 Q4
Start-up of INCO incubators and brief training (Germany only) through Memmert service. Service not subject to any discount K9 K9 K9
Guarantee extension to 3 years Q5 Q5 Q5