![]()
Cell cultures, tissue cultures and bacteria cultures, as well as micro-organisms, need protection in a controlled and physiologically ideal environment.
Alarm functions, three-fold overtemperature protection and simultaneous display of all parameters provide safety for samples and cultures in medicine, life science, environmental technology, bacteriology, virology, biology, biotechnology and zoology.
- Temperature range up to +50 ℃
- 3 model sizes (108l, 153l and 246l)
- The standard INCO appliance can be expanded with 7additional modules
- State-of-the-art control technology based on the P performance class for all models
- Humidity limit control integrated as standard for all models (humidity module with active humidity control system at extra charge)
- For all models, the inner chamber, including all fittings and all sensors, can be sterilised at 160°C in a 4 hour programme, using the standard STERICard
We never save on essentials. Even in the attractively-priced standard model, the CO2 incubator INCO offers unparalleled precision and reliability. Do you have any further requirements in addition to this? You can put together your own customised INCO from 7 optional and freely combinable additional modules.
- Comfort module: Two gas connections with quick release connectors, automatic switch-over between gas bottles (a combination of the comfort module and the O2 module is not possible, since N2 introduction takes place via the second gas bottle connection)
- Hygiene module: electropolished, seamless laser-welded chamber
- Communication module: USB interface, “Celsius” standard software for programming and logging, ring memory, printer port
- CO2 module: Extended CO2 range from 0 to 20%
- O2 module: Control of oxygen concentration through the introduction of nitrogen, setting range from 1% to 20% O2(a combination of the comfort module and the O2 module not possible, since the N2 introduction takes place via the second gas bottle connection)
- Premium module: Includes comfort, hygiene, communication and CO2 modules
- Humidity module: active microprocessor humidification and dehumidification control (40-97% rh)
For the INCO, the tried and tested Memmert heating concept was once again perfected: heating the inner chamber from all six sides, along with the electronic humidity limit control, is decisive in preventing condensation from forming in the inner chamber, while offering maximum protection to your cell cultures. An aluminium thermal conductive layer supports optimum temperature distribution, and serves as a heat accumulator in case of a temporary power failure. The turbulence-free chamber ventilation ensures a constant and uniform atmosphere.
60 years of permanent development work, as well as numerous amounts of feedback from practical experience, are embodied in each of our appliances:
- The modular manufacturing concept in accordance with the principle of equal parts enables a highly varied and cost-effective production
- Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
- Heating concept adapted to the specific product for a precise and homogenous temperature control independent of chamber volume and load
- A wide range of options for programming and documentation using interfaces, Celsius software, integrated log memory and chip cards (features dependent on the controller class)
- Two-year guarantee for appliances sold outside Germany
- Each CO2 incubator is safety-tested and bears this sign:
Incubator
The Memmert incubator I is ideally suited to incubation at temperatures of up to 70 °C - specifically for the in-vitro incubation of cell cultures, tissue cultures and bacteria cultures at 37 °C.
Peltier-cooled incubator
Not having a compressor creates more space, brings calm to the laboratory and creates an extremely low-vibration environment for living cultures in the IPP Peltier-cooled incubator.
Environment technology
Application in-vitro incubation of bacteria cultures: Hygiene is the top priority when testing drinking water for Legionella bacteria.
Biology for all
The incubation of bacteria cultures in an incubator proved at an exhibition in Dublin how dangerous kisses can be!




