|  |
100 |
200 |
300 |
400 |
500 |
| Perforated stainless steel shelf |
 |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
| Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) |
 |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
| Stainless Steel Grid (for good air circulation) |
 |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
| Bottom drip tray |
 |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
| Wall bracket (tubular frame for wall mounting) |
 |
G0 |
G0 |
G0 |
G0 |
G0 |
| Stacking version for 2 ovens of equal size (bottom oven modification) |
 |
G3 |
G3 |
G3 |
G3 |
G3 |
| Subframe adjustable in height (height min. 622 mm) |
 |
- |
- |
- |
- |
G5 |
| Subframe, but with castors (height 622 mm) |
 |
- |
- |
- |
- |
G6 |
| Plug-in tube extension straight (l 88 mm, outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) |
 |
G7 |
G7 |
G7 |
G7 |
G7 |
| Plug-in tube extension angled (outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) |
 |
G8 |
G8 |
G8 |
G8 |
G8 |
|  |
200 |
300 |
400 |
500 |
550 |
600 |
700 |
800 |
| Temperature range +300 °C for universal ovens (not available for ovens with glass door) |
|
A0 |
A0 |
A0 |
A0 |
A0 |
A0 |
A0 |
A0 |
| Adjustable temperature limiter, safety device class 2 instead of adjustable overheat controller safety device class 3.1 |
|
A5 |
A5 |
A5 |
A5 |
A5 |
A5 |
A5 |
A5 |
| Full-sight glass door (triple-insulating glass) for series UN/UF (extra) |
 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
| Stainless-steel doors (can be used up to 300 °C) with triple insulating glass window |
|
- |
- |
- |
- |
- |
B1 |
B1 |
B1 |
| Locking door (security lock) |
 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
| Door-hinges on left side |
|
B8 |
B8 |
B8 |
B8 |
B8 |
- |
- |
- |
| Perforated stainless steel shelf |
 |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
E0(x) |
| Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) |
 |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
E2(x) |
| Stainless Steel Grid (for good air circulation) |
 |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
E3(x) |
| Bottom drip tray |
 |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
E8(x) |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/centre |
 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/top |
 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/centre |
 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/top |
 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
| Other port 23 mm diameter left |
 |
F4(x) |
F4(x) |
F4(x) |
F4(x) |
F4(x) |
F4(x) |
F4(x) |
F4(x) |
| Other port 23 mm diameter right |
 |
F5(x) |
F5(x) |
F5(x) |
F5(x) |
F5(x) |
F5(x) |
F5(x) |
F5(x) |
| Other port 23 mm diameter, in special positions in the back wall (please state location) |
 |
F6(x) |
F6(x) |
F6(x) |
F6(x) |
F6(x) |
F6(x) |
F6(x) |
F6(x) |
| Other port (38 mm diam.) at the back as per your specification |
 |
F7(x) |
F7(x) |
F7(x) |
F7(x) |
F7(x) |
F7(x) |
F7(x) |
F7(x) |
| Wall bracket (tubular frame for wall mounting) |
 |
G0 |
G0 |
G0 |
G0 |
G0 |
G0 |
G0 |
- |
| Flush-fit unit (stainless steel frame covering gap between oven and wall opening) |
 |
G1 |
G1 |
G1 |
G1 |
G1 |
G1 |
G1 |
G1 |
| Stacking version for 2 ovens of equal size (bottom oven modification) |
 |
G3 |
G3 |
G3 |
G3 |
G3 |
G3 |
G3 |
- |
| Subframe adjustable in height (height min. mm: size 500-600: 622, size 700: 572) |
 |
- |
- |
- |
G5 |
G5 |
G5 |
G5 |
- |
| Subframe with castors (height: size 500-600: 622 mm, size 700: 572 mm) |
 |
- |
- |
- |
G6 |
G6 |
G6 |
G6 |
- |
| Interface USB instead of interface RS232 |
|
W3 |
W3 |
W3 |
W3 |
W3 |
W3 |
W3 |
W3 |
| USB connection cable for computer interface |
 |
W7 |
W7 |
W7 |
W7 |
W7 |
W7 |
W7 |
W7 |
| Connection cable for computer interface RS232 according to DIN 12 900-1 |
 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
| Fresh-air filter (filtration efficiency 80%) and additional subframe (for sizes 400-700) |
 |
- |
- |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
| Flexible Pt100 for positioning in chamber or load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) |
 |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
| Interior lighting (up to size 600: 15 W, size 700/800: 2 x 15 W) |
 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
| Interior nearly gastight (UN/IN), 20% pre-payment required |
|
- |
- |
K2 |
K2 |
K2 |
- |
- |
- |
| Interior nearly gastight (UN/IN) with possibility for gas inlet/outlet through tube(s) with ball valves |
|
- |
- |
K3 |
K3 |
K3 |
- |
- |
- |
| Plug-in tube extension straight (l 88 mm, outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) |
 |
G7 |
G7 |
G7 |
G7 |
G7 |
G7 |
G7 |
G7 |
| Plug-in tube extension angled (outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) |
 |
G8 |
G8 |
G8 |
G8 |
G8 |
G8 |
G8 |
G8 |
| Works calibration certificate at three temperatures: 100 °C, 160 °C, 220 °C |
 |
Z2 |
Z2 |
Z2 |
Z2 |
Z2 |
Z2 |
Z2 |
Z2 |
| Works calibration certificate (IN) at three temperatures: 37 °C, 52 °C, 70 °C |
 |
Z4 |
Z4 |
Z4 |
Z4 |
Z4 |
Z4 |
Z4 |
Z4 |
| IQ check list with works test data for oven as support for validation by customer |
|
Q1 |
Q1 |
Q1 |
Q1 |
Q1 |
Q1 |
Q1 |
Q1 |
| OQ check list including one free-selectable temperature distribution survey to DIN 12880: 2007-05 (size 200/300: 9 measuring points, size 400-800: 27 measuring points) with works test data for oven as support for validation by customer |
|
Q2 |
Q2 |
Q2 |
Q2 |
Q2 |
Q2 |
Q2 |
Q2 |
|  |
200 |
300 |
400 |
500 |
550 |
600 |
700 |
800 |
| Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps |
 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
| Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) |
 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
| STERICard (additional or as replacement) for automatic incubator chamber sterilisation cycle (not for sterilising the load!) |
 |
V9 |
V9 |
V9 |
V9 |
V9 |
V9 |
V9 |
V9 |
| Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties |
 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
V1 |
| Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface RS232 |
 |
V2 |
V2 |
V2 |
V2 |
V2 |
V2 |
V2 |
V2 |
| Interface Ethernet instead of RS232 inclusive software "Celsius Ethernet-Edition" |
|
W4 |
W4 |
W4 |
W4 |
W4 |
W4 |
W4 |
W4 |
| Parallel/USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units. Compatible with USB 1.1 and USB 2.0 |
 |
W1 |
W1 |
W1 |
W1 |
W1 |
W1 |
W1 |
W1 |
| Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6940 or successor) for direct connection of printer to Memmert unit |
 |
W2 |
W2 |
W2 |
W2 |
W2 |
W2 |
W2 |
W2 |
| Process-dependent electromagnetic door lock (pre-payment of 20% required) |
|
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
| Reinforced chamber - includes replacement of 2 standard shelves by 2 reinforced shelves - (pre-payment of 20% of total required); total height increases by 20 mm (mod. 500 - 700) resp. by 45 mm (mod. 800). |
|
- |
- |
- |
K1 |
K1 |
K1 |
K1 |
K1 |
| Perforated stainless steel shelf, reinforced for heavy loads (involves reinforced chamber; 20% pre-payment required) |
 |
- |
- |
- |
E1(x) |
E1(x) |
E1(x) |
E1(x) |
E1(x) |
| Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached) |
 |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
| Potential-free contact (24V/2A) for combined fault message (e.g. supply failure, sensor fault, fuse) |
 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
| Floating triple contact, for signal generation, controlled by programme segment (using PC), for a total of 3 freely selected functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers etc.) |
 |
H7 |
H7 |
H7 |
H7 |
H7 |
H7 |
H7 |
H7 |
| Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. |
|
H8(x) |
H8(x) |
H8(x) |
H8(x) |
H8(x) |
H8(x) |
H8(x) |
H8(x) |
| Software conforming to FDA "Celsius FDA-Edition" for up to 16 units |
|
Q3 |
Q3 |
Q3 |
Q3 |
Q3 |
Q3 |
Q3 |
Q3 |
| Integration of additional units (up to max.16 units) into an already existent FDA-software licence |
|
Q4 |
Q4 |
Q4 |
Q4 |
Q4 |
Q4 |
Q4 |
- |