200 |
400 |
500 |
| Additional thermoshelves of stainless steel material no. 1.4404 (ASTM 316 L) with integrated large area heating including local temperature sensing (Pt100, 4 wire circuit), Multi-Level Overtemperature Control (MLOP) for each thermoshelf and calibration certificate (if ordered at the same time as the vacuum oven) |
 |
E8(x) |
E8(x) |
E8(x) |
| Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps |
 |
V3 |
V3 |
V3 |
| Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) |
 |
V4 |
V4 |
V4 |
| Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties |
 |
V1 |
V1 |
V1 |
| Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface RS232 |
 |
V2 |
V2 |
V2 |
| Interface USB instead of interface RS232 |
|
W3 |
W3 |
W3 |
| Interface Ethernet instead of RS232 inclusive software "Celsius 2007 Ethernet-Edition" |
|
W4 |
W4 |
W4 |
| Parallel/USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units. Compatible with USB 1.1 and USB 2.0 |
 |
W1 |
W1 |
W1 |
| Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6940 or successor) for direct connection of printer to Memmert unit |
 |
W2 |
W2 |
W2 |
| Connection cable for computer interface RS232 according to DIN 12 900-1 |
 |
V6 |
V6 |
V6 |
| Flexible Pt100 for positioning in chamber of vacuum oven or in load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) |
|
H4 |
H4 |
H4 |
| Works calibration certificate at three temperatures: 50 °C, 100 °C, 160 °C at 50 mbar pressure |
|
Z6(x) |
Z6(x) |
Z6(x) |
| IQ check list with works test data for oven as support for validation by customer |
|
Q1 |
Q1 |
Q1 |
| OQ check list (including one free-selectable thermoshelf temperature distribution survey for 5 measuring points to DIN 12880: 2007-05) with works test data for oven as support for validation by customer |
|
Q2 |
Q2 |
Q2 |
| Software conforming to FDA "Celsius 2007 FDA-Edition" |
|
Q3 |
Q3 |
Q3 |
| Noise absorbing vacuum pump module without pump with antivibration metal plate to accomodate the vacuum pump. Full-sight glass door. Socket and connecting hose to the vacuum oven. Signal cable for optimising pump performance by demand-controlled activation of purge of Memmert pump. (External dimensions same as vacuum oven) |
 |
PM |
PM |
PM |
| Noise absorbing vacuum pump module with integrated pump (chemically resistant vacuum pump with PTFE double diaphragm and automatic purge process through controller of vacuum oven) incl. energy-saving pump control. 230 V, 50 Hz (other voltages upon request). Pump capacity at atm. pressure of approx. 34 Nl/min =2,04 m³/h for VO 200; approx. 60 Nl./min = 3.6 m³/h for VO 400 and 500. Anti-vibration metal plate to accomodate the vacuum pump. Full-sight glass door. Socket and connecting hose to the vacuum oven. Signal cable for optimising pump performance by demand-controlled activation of purge of Memmert pump. Max. guarantee for pump: 2 years. (External dimensions same as vacuum oven) |
 |
PMP |
PMP |
PMP |
| Chemically resistant vacuum pump with PTFE double diaphragm; pump capacity at atm. pressure of approx. 34 Nl/min = 2,04 m³/h and automatic purge process through controller of vacuum drying oven. Items n° V7 + V8 required in addition. 230 V, 50/60 Hz, other voltages upon request. |
 |
K5 |
- |
- |
| Chemically resistant vacuum pump with PTFE double diaphragm; pump capacity at atm. pressure of approx. 60 Nl/min = 3,6 m³/h and automatic purge process through controller of vacuum drying oven. Items n° V7 + V8 required in addition. 230 V, 50/60 Hz, other voltages upon request. |
 |
- |
K6 |
K6 |
| Signal cable (3m) for optimising pump performance by demand-controlled activation of purge of Memmert pump. Not required when ordering pump module with pump (or if they are already available). |
 |
V7 |
V7 |
V7 |
| Vacuum connecting hose (3m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel). Not required when ordering pump module with pump (or if they are already available). |
 |
V8 |
V8 |
V8 |
| Subframe, steel tube, black lacquered (for stacking unit consisting of vacuum drying oven and pump module, total height: 1650 mm) |
 |
G5 |
G5 |
G5 |