Peltier-Cooled Incubators IPP

Revolutionary energy-saving heating/cooling technology combination

(Click on image to enlarge!)
IPP 500 - Peltier-cooled incubator

Excellent controllability, extremely small control fluctuations, low-vibration operation and impressive energy savings provide the added value from this perfect adaptation of Peltier technology. Memmert holds the leading position in this technologically sophisticated market segment. Your decision criteria for the IPP models:

  • 5 model sizes (32l to 108l and 749l)
  • State-of-the-art control technology based on the P performance class for all models
  • Double doors standard for all models: Prevention of contamination and drops in temperature, with at the same time an optimal view of the sensitive load through wide-area interior glass doors
  • Forced air circulation ensures rapid energy transport and optimal temperature uniformity

Not having a compressor creates more space, brings calm to the laboratory and provides living cultures with an extremely low-vibration environment. With an interior volume of up to 108 litres, the IPP models offer a minimum energy consumption with maximum benefit to the environment, because in contrast to compressor technology, energy is only required when you need to heat or cool down.

The working chamber of the IPP is completely sealed off from the environment. The advantages for you: minimal risk of the sample drying out, condensation formation during the cooling down process takes place outside the working chamber on the Peltier element.

With the help of our model selection you can find the right model for your needs, with dimensioned model sketches and extensive technical data for download. For large volumes in conjunction with rapid temperature change, the Memmert compressor-cooled incubators are recommended. We are convinced that the flexibility and technical features of our appliances meet all possible needs. Put us to the test!

60 years of permanent development work, as well as numerous amounts of feedback from practical experience are embodied in each of our appliances:

  • The modular manufacturing concept in accordance with the principle of equal parts enables a highly varied and cost-effective series production
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • A wide range of options for programming and documentation using interfaces, Celsius software, integrated log memory and chip cards
  • Peltier-cooled incubators are safety-tested and bear the sign:

European Conformity sign