In terms of thermal safety and operating comfort, the highest Memmert controller class is uncompromisingly perfect for the Memmert Incubator I. Complex thermal processes in food chemistry, biology and pharmaceutics are programmed without any problems and repeated as often as necessary with the help of a chip card. A multifunctional fuzzy controller, with permanent performance adjustments and integrated self-diagnosis system, as well as two high-quality platinum temperature sensors Pt100, ensure absolutely reliable temperature control in the incubator, as well as the highest process safety and control accuracy.
- Temperature range: 30 °C (at least 5 °C above ambient) to 70 °C
- Temperature variation (time): < ±0.05 °C at 37 °C
- Multiple overtemperature protection: If the electronic heating control should fail, heating is switched off at a fixed level of 3 °C above the setpoint. An adjustable overtemperature controller TWW protection class 3.1 (optional adjustable electronic temperature limiter TWB protection class 2) takes over control at a preset temperature in case of failure. ASF Automatic Safety Function - a unique safety function - for over- and undertemperature automatically following the setpoint in a freely selectable tolerance range. An alarm sound is activated in case of over- /undertemperature, and the heating is switched off in case of overtemperature. In addition a mechanical temperature limiter, TB, switches off heating permanently if the maximum permitted oven temperature is exceeded by approx. 10 °C.
- Adjustable undertemperature alarm
- 2 high-grade platinum temperature sensors Pt 100 in a 4-wire circuit (for stable long-term transmission of measurement signals) communicate with each other and ensure uninterrupted error-free temperature control at constant working temperature
- Digital programme control (programmable to the minute) for temperature profiles consisting of up to 40 ramp segments
- Weekly programme timer programmable to the minute
- Air flap adjustable by servo motor for fresh air intake
- Speed of fan can be controlled at 10% intervals, or shut down (IF)
- Heating power distribution balance to optimise temperature uniformity
- Simultaneous display of all parameters, such as temperature, weekday, time, fan speed (IF), air flap position and number of ramps
- Visual and acoustic alarm in case of over/undertemperature
- Alphanumeric text display in different languages (D/UK/E/F/I)
- Function signals for stand-by, operating mode, heating and over/undertemperature
- Internal log memory with 1024kB to save temperature and error states, with timestamp to the minute
- Chip card control including 1 MEMoryCard XL with 32 kB memory capacity (max. 40 ramps)
- 2nd chip card (STERICard) for working chamber sterilisation with fixed set values (4 hrs/160 °C)
- Serial RS-232 communication interface (option: USB) and software Celsius to control the appliance and to read out the appliance's internal log memory
- Parallel printer interface for printout of log data via an external PCL3-compatible inkjet printer (USB available via converter)
Peltier-Cooled Incubator
Not having a compressor creates more space, brings calm to the laboratory and provides living cultures with an extremely low-vibration environment in the IPP Peltier-cooled incubator.
CO2 incubator INCO
Ideal for research and medicine! Taking the standard INCO model and 7 additional modules, you can put together your own customised CO2 incubator.
Research for all
The incubation of bacteria in an incubator proved at an exhibition in Dublin how dangerous kisses can be!
Application Biology
Without noises and vibrations: In the laboratory of the Würzburg BEEgroup, many bees began life in a cooled Memmert Incubator IPP.