Low-vibration: A constant climate chamber that you (almost) cannot hear

How to find your order number:

e.g. HPP 108 E0(2) H5
Basic appliance code + Accessories code in any order plus quantity (x) required

Model sizes 108749
Cold white light module (5,500 Kelvin); 10 LED light strips arranged on the side wall of the interior, illumination strength 10,000 LUX, programme-controlled dimming from 0 to 100% in 10 % steps, ramp programming in combination with temperature and humidity T7 -
Cold white light module 5,500 Kelvin + warm white 2,700 Kelvin; 10 LED light strips (5 alternating cold white light strips and 5 warm white light strips) arranged on the side wall of the interior, illumination strength 10,000 LUX, programme-controlled dimming from 0 to 100% in 10 % steps, ramp programming in combination with temperature and humidity T8 -
Locking door (security lock) B6 B6
Perforated stainless steel shelf E0(x) E0(x)
Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) E2(x) E2(x)
Stainless Steel Grid E3(x) E3(x)
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, left centre/centre F0 F0
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, left centre/top F1 F1
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, right centre/centre F2 F2
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, right centre/top F3 F3
Stacking version for 2 ovens of equal size (bottom oven modification) G3 -
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps V3 V3
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) V4 V4
Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties V1 V1
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB V2 V2
RS232 interface instead of USB W6 W6
Interface Ethernet instead of USB inclusive software "Celsius Ethernet-Edition" W4 W4
Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. W1 W1
Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit W2 W2
USB connection cable for computer interface W7 W7
Flexible Pt100 for positioning in chamber or load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) H4 H4
Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached) H5 H5
Potential-free contact (24V/2A) for combined fault message (e.g. supply failure, sensor fault, fuse) H6 H6
Floating triple contact, for signal generation, controlled by programme segment (using PC), for a total of 3 freely selected functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers etc.) H7 H7
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. H8(x) H8(x)
Works calibration certificate for one temperature and humidity according to customer specification Z4 Z4
IQ check list with works test data for oven as support for validation by customer Q1 Q1
OQ check list with works test data for one freely selectable humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 as support for validation by customer Q2 Q2
Software conforming to FDA "Celsius FDA-Edition" for up to 16 units Q3 Q3
Integration of additional units (up to max.16 units) into an already existent FDA-software licence Q4 Q4
Guarantee extension by 1 year Q5 Q5