Need personal assistance?

Memmert Customer Service

+49(0)9122/925-222

Technologies applied

Control technology
In terms of thermal safety and operating comfort, the highest Memmert controller class is uncompromisingly perfect.

All-round surface heating
Optimum temperature distribution is just one of many advantages in our unique heating concept.

Highly sensitive extremely accurate: Incubator I

In the laboratory, our incubator is ideal for all applications with temperatures up to +70°C – specifically for incubating living cultures at +37 °C. Thanks to the finely-tuned control technology, critical temperature overshoots are completely ruled out, valuable loads are therefore warmed up particularly carefully.

  • Temperature range up to +70 °C
  • 8 model sizes (32l to 749l)
  • 3 performance classes Basic/Excellent/Perfect
  • Natural convection or forced air circulation N/F
  • Double doors (interior glass, exterior stainless steel) for a clear view without a drop in temperature
  • Sterilisation of chamber via STERICard (P class)

Memmert incubator - A gentle force in the laboratory

So that we can ensure optimum air circulation in the incubator chamber even when it is fully loaded, we have equipped our controller classes Excellent and Perfect with an adjustable air fan. Since our unique all-round surface heating is optimally geared to both natural convection and forced air circulation, the fan can be switched off entirely for sensitive samples and for samples which may not be exposed to air turbulence. 

Specific use in accordance with the German MPG (Law on Medical Devices)

In accordance with the German Law on Medical Products (Directive 93/42/EEC), the incubators INP can be used for the warming of irrigation solutions and infusions.

Stainless steel – an incubator (almost) for ever

60 years of permanent development work, as well as numerous amounts of feedback from practical experience, are embodied in each of our incubators:

  • The modular manufacturing concept in accordance with the principle of equal parts enables a highly varied and cost-effective production
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Heating concept adapted to the specific product for a precise and homogenous temperature control independent of chamber volume and load
  • A wide range of options for programming and documentation using interfaces, Celsius software, integrated log memory and chip cards (features dependent on the controller class)
  • Three-year guarantee for appliances except wear and tear parts 
  • The temperature values of all incubators are measured according to DIN 12880:2007-05
  • Each incubator is safety-tested and bears this sign: