Need personal assistance?

Memmert Customer Service

+49(0)9122/925-222

Technologies applied

All-round surface heating
Through this type of construction, natural turbulence is created, providing optimum temperature distribution in the waterbath.

Material stainless steel
Over many years of practical use, high-grade stainless steel has proved to be superior to coated sheet steel, which can corrode rapidly during extended use.

A heating bath with state-of-the-art comfort and the highest degree of safety

The Memmert waterbath is available in six model sizes and two performance classes. In addition to the Basic class for standard temperature control tasks, the Excellent version provides precise test procedures with a maximum of safety: electronic overtemperature control and a wide range of visual and acoustic signals; for example if the filling level is too low, for overtemperature, but also for input acknowledgement or to signalise the end of the programme. In the largest model, an optional circulation pump provides an even better thermal uniformity of the water.

  • Temperature range up to +95 °C (with Peltier cooling unit CDP 115 from +10 °C)
  • 6 model sizes (7l to 45l)
  • An extensive range of optional accessories is available: e.g. a Peltier cooling unit, flat or gable lid, shaking device, floor grid, test tube rack
  • State-of-the-art control technology of the Basic and Excellent performance classes for all models
  • Can be optionally equipped with water level control

Heating concept with dual benefits

The superior heating concept of the Memmert ovens can also be found in the waterbaths. Protected from water, but still close to the load, the heating lies under deep-drawn and easy to clean ribs. The heating elements can therefore neither corrode nor become furred. Through their positioning in the floor and side walls, a natural mixing of the temperature control fluid arises, providing better temperature distribution in the bath. 

Waterbath cooling with Peltier technology

When setpoint temperatures close to the ambient temperature are required in the waterbath to be as constant as possible, the unique Peltier cooling unit CDP 115 cools the medium water down to 10 °C precisely, economically and in an eco-friendly way, with a precision of ±0.1 K. For all appliances from 7 to 45 litres it can be easily retrofitted, without any technical knowledge. Your benefits:

  • No gases or fluids (coolants) required, and therefore no hazardous waste
  • Exceptionally quiet and smooth-running because of the Peltier technology
  • High degree of control precision in combination with the electronic controller of the Memmert waterbath
  • Saves valuable space in the laboratory

Stainless steel – a waterbath (almost) for ever

60 years of permanent development work, as well as numerous amounts of feedback from practical experience, are embodied in each of our appliances:

  • The modular manufacturing concept in accordance with the principle of equal parts enables a highly varied and cost-effective production
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Heating concept adapted to the specific product for a precise and homogenous temperature control independent of chamber volume and load
  • A wide range of options for programming and documentation using interfaces, Celsius software, integrated log memory and chip cards (features dependent on the controller class)
  • Three-year guarantee for appliances except wear and tear parts 
  • Each heating bath is safety-tested and bears this sign: