Climate Chamber for stability tests in accordance with GMP and ICH

How to find your order number:

e.g. ICH 256L E0(2) H4
Basic appliance code + Accessories code in any order plus quantity (x) required

Model sizes 256256L256C
Alternative illumination boxes (replace the standard lighting; order has to be placed together with the chamber): 6 fluorescent lights with cold white light (standard illuminant D65, 6.500 K) - T8 -
Alternative illumination boxes (replace the standard lighting; order has to be placed together with the chamber): 6 UV lamps in the spectral range of 315 – 400 nm - T0 -
Light intensity measuring via external measuring instrument - D6 -
Water connection for external fresh water supply D7 D7 D7
Locking door (security lock) B6 B6 B6
Perforated stainless steel shelf E0(x) E0(x) E0(x)
Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) E2(x) E2(x) E2(x)
Stainless Steel Grid E3(x) E3(x) E3(x)
Other moisture-tight entry ports (inner dia. 40 mm), in special positions in the back wall, can be closed from inside by silicone stopper (please state location) F7(x) F7(x) F7(x)
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps V3 V3 V3
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) V4 V4 V4
Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties V1 V1 V1
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB V2 V2 V2
RS232 interface instead of USB W6 W6 W6
Interface Ethernet instead of USB inclusive software "Celsius Ethernet-Edition" W4 W4 W4
Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. W1 W1 W1
Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit W2 W2 W2
USB connection cable for computer interface W7 W7 W7
Flexible Pt100 for positioning in chamber or load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) H4 H4 H4
Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached) H5 H5 H5
Potential-free contact (24V/2A) for combined fault message (e.g. supply failure, sensor fault, fuse) H6 H6 H6
Pressure reducing valve to DIN 8546, incl. gas cylinder monitor - - H7
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. H8(x) H8(x) H8(x)
Works calibration certificate for one temperature and humidity according to customer specification Z4 Z4 Z4
Works calibration certificate for 5%, 7% and 10% CO2 (measured at 37 °C) - - Z5
IQ check list with works test data for oven as support for validation by customer Q1 Q1 Q1
OQ check list including one free-selectable temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 with works test data for incubator as support for validation by customer Q2 Q2 Q2
Software conforming to FDA "Celsius FDA-Edition" for up to 16 units Q3 Q3 Q3
Integration of additional units (up to max.16 units) into an already existent FDA-software licence Q4 Q4 Q4