Humidity chamber HCP

Active humidity control creates a controlled environment for accelerated life tests and 85/85 tests.

Humidity chamber with active humidity control set HCP150 560 x 700 x 400 mm | Memmert

Perfect environmental simulation in the humidity chamber
Climate chamber with active humidity control

This climate chamber offers the full range of comfort, reliability, and safety. It has active humidity control set from 20 % to 95 % rh and an unsurpassed homogeneity of temperature and humidity over the entire interior. It is suited for environmental testing, environmental simulation, accelerated service life tests, and 85/85 tests according to IEC 60068-2-67 and IEC 60068-2-78.
  • Temperature range up to +90 °C
  • 4 model sizes (56 to 241 litres volume)
  • 1 model variant: TwinDISPLAY
  • Active humidity control 20 to 95 % rh
  • Double doors as standard:
  • 1. Prevention of contamination
  • 2. Prevention of drops or rises in temperature
  • 3. An optimal view of the sensitive chamber load through wide-area heated inner glass door

Humid environment without condensation

The active humidity control ensures an ideal homogeneity of temperature, humidity as well as short recovery times after opening the door. It is practically a maintenance-free climate chamber.
In combination with the heating on all six sides, including a heated inner glass door, it also minimises vaporisation in the interior and, thus, the risk of condensed water dripping onto the test object.
An aluminium thermal conductive layer supports optimum temperature distribution and serves as a heat accumulator in case of a temporary power failure.

Comfortable equipment for accelerated service life tests

To ensure that environmental tests and accelerated life tests such as 85/85 tests run reliably and safely, the humidity chamber HCP offers a wide range of comfort functions:
1. Standard feed-through on the rear panel
2. Battery-buffered ControlCOCKPIT (option)
3. Process runtime starts with SetpointWAIT function only when the setpoint temperature is reached
4. Alarm messages can be sent via e-mail or SMS with MobileALERT (option) and much more.

A Memmert humidity chamber offers unique advantages

  • intuitive and easy-to-use operating menu
  • Heating concept specifically adapted for a precise and homogenous temperature control
  • A wide range of options for programming and documentation of different temperature/humidity profiles via Software AtmoCONTROL
  • Alarm functions, three-fold overtemperature protection and simultaneous display of all parameters provide safety for samples and cell cultures
  • almost exclusive use of high-quality and easily cleanable stainless steel for the working chamber and housing
  • 3 years guarantee worldwide

Temperature Humidity Working Range HCP

Not all climate chambers are the same. The humidity content of the chamber load, the ambient conditions and the respective temperature-humidity working range are decisive factors in the selection of the right appliance. In the adjacent diagram, you can see the possible temperature/humidity combinations for our humidity chambers HCP.

Within the respective temperature-humidity range, permanent operation is possible (at an ambient temperature of 22 °C ± 3 K, relative humidity < 50 %). Condensation may occur in the threshold range. To which extent depends on the humidity content of the chamber load and the ambient conditions.

Standard units are safety-approved and bear the test marks

CE
VDEGS
cMET
EAC Eurasian Conformity