Incubating, drying, storing – quality control in the industry

How to find your order number:

e.g. ICP 500 E0(2) H4
Basic appliance code + Accessories code in any order plus quantity (x) required

Model sizes 400500600700800
Locking door (security lock) B6 B6 B6 B6 B6
Perforated stainless steel shelf E0(x) E0(x) E0(x) E0(x) E0(x)
Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) E2(x) E2(x) E2(x) E2(x) E2(x)
Stainless Steel Grid E3(x) E3(x) E3(x) E3(x) E3(x)
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/centre F0 F0 F0 F0 F0
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/top F1 F1 F1 F1 F1
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/centre F2 F2 F2 F2 F2
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/top F3 F3 F3 F3 F3
Other port 23 mm diameter, in special positions in the back wall (please state location) F6(x) F6(x) F6(x) F6(x) F6(x)
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps V3 V3 V3 V3 V3
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) V4 V4 V4 V4 V4
Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties V1 V1 V1 V1 V1
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB V2 V2 V2 V2 V2
RS232 interface instead of USB W6 W6 W6 W6 W6
Interface Ethernet instead of USB inclusive software "Celsius Ethernet-Edition" W4 W4 W4 W4 W4
Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. W1 W1 W1 W1 W1
Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit W2 W2 W2 W2 W2
USB connection cable for computer interface W7 W7 W7 W7 W7
Connection cable for computer interface RS232 according to DIN 12 900-1 V6 V6 V6 V6 V6
Flexible Pt100 for positioning in chamber or load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) H4 H4 H4 H4 H4
Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached) H5 H5 H5 H5 H5
Potential-free contact (24V/2A) for combined fault message (e.g. supply failure, sensor fault, fuse) H6 H6 H6 H6 H6
Floating triple contact, for signal generation, controlled by programme segment (using PC), for a total of 3 freely selected functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers etc.) H7 H7 H7 H7 H7
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. H8(x) H8(x) H8(x) H8(x) H8(x)
Interior lighting (programme-segment-dependent switching on/off by process controller, for example day/night simulation), fluorescent lamps at the back (size 500: 6 lamps each 15 W / approx. 1000 Lux; size 600: 6 lamps each 18 W / approx. 2500 Lux; size 700: 6 lamps each 18 W / approx. 1000 Lux; size 800: 6 lamps each 30 W / approx. 2500 Lux). Thermally isolated illumination box with insulating glass window and reflectors. - R2 R2 R2 R2
Works calibration certificate at three temperatures: 0 °C, 37 °C, 60 °C Z4 Z4 Z4 Z4 Z4
IQ check list with works test data for oven as support for validation by customer Q1 Q1 Q1 Q1 Q1
OQ check list including one free-selectable temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 with works test data for incubator as support for validation by customer Q2 Q2 Q2 Q2 Q2
Software conforming to FDA "Celsius FDA-Edition" for up to 16 units Q3 Q3 Q3 Q3 Q3
Integration of additional units (up to max.16 units) into an already existent FDA-software licence Q4 Q4 Q4 Q4 Q4