| Flow meter for N2 gas |
|
T1 |
T1 |
| Lockable castors (drwg. D10680 -height of casing 1620 mm) |
|
- |
T2 |
| Lateral entry port - height 23 mm / width individual |
|
T3 |
T3 |
| Adjustable temperature limiter, safety device class 2 instead of adjustable overheat controller safety device class 3.1 |
|
A5 |
A5 |
| Full-sight glass door (triple-insulating glass) for series UN/UF (extra) |
 |
B0 |
B0 |
| Locking door (security lock) |
 |
B6 |
B6 |
| Perforated stainless steel shelf |
 |
E0(x) |
E0(x) |
| Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) |
 |
E2(x) |
E2(x) |
| Stainless Steel Grid |
 |
E3(x) |
E3(x) |
| Bottom drip tray |
 |
E8(x) |
E8(x) |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/centre |
 |
F0 |
F0 |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/top |
 |
F1 |
F1 |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/centre |
 |
F2 |
F2 |
| Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/top |
 |
F3 |
F3 |
| Other port 23 mm diameter left |
 |
F4(x) |
F4(x) |
| Other port 23 mm diameter right |
 |
F5(x) |
F5(x) |
| Flush-fit unit (stainless steel frame covering gap between oven and wall opening) |
 |
G1 |
G1 |
| Interface USB instead of interface RS232 |
|
W3 |
W3 |
| USB connection cable for computer interface |
 |
W7 |
W7 |
| Reinforced chamber - includes replacement of 2 standard shelves by 2 reinforced shelves total height increases by 20 mm (mod. 500 - 700) resp. by 45 mm (mod. 800). |
|
K1 |
K1 |
| Reinforced stainless steel grid (only for Class P with reinforced chambers) |
|
E4(x) |
E4(x) |
| Flexible Pt100 for positioning in chamber or load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) |
 |
H4 |
H4 |
| Works calibration certificate at three temperatures: 100 °C, 160 °C, 220 °C |
 |
Z2 |
Z2 |
| IQ check list with works test data for oven as support for validation by customer |
|
Q1 |
Q1 |
| OQ check list including one free-selectable temperature distribution survey to DIN 12880: 2007-05 (size 200/300: 9 measuring points, size 400-800: 27 measuring points) with works test data for oven as support for validation by customer |
|
Q2 |
Q2 |
| Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps |
 |
V3 |
V3 |
| Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) |
 |
V4 |
V4 |
| Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties |
 |
V1 |
V1 |
| Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface RS232 |
 |
V2 |
V2 |
| Interface Ethernet instead of RS232 inclusive software "Celsius Ethernet-Edition" |
|
W4 |
W4 |
| Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. |
 |
W1 |
W1 |
| Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit |
 |
W2 |
W2 |
| Process-dependent electromagnetic door lock |
|
D4 |
D4 |
| Locking mechanism with SPS control to prevent simultaneous opening of doors for contamination protection in case of wall installation |
|
D5 |
D5 |
| Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached) |
 |
H5 |
H5 |
| Potential-free contact (24V/2A) with socket, 3-pin, according to NAMUR NE 28, for combined fault message of temperature and CO2 controller (e.g. supply failure, sensor fault, fuse) |
 |
H6 |
H6 |
| Potential-free contact (24V/2A) for combined fault message (e.g. supply failure, sensor fault, fuse) |
 |
H6 |
H6 |
| Floating triple contact, for signal generation, controlled by programme segment (using PC), for a total of 3 freely selected functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers etc.) |
 |
H7 |
H7 |
| Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. |
|
H8(x) |
H8(x) |
| Software conforming to FDA "Celsius FDA-Edition" for up to 16 units |
|
Q3 |
Q3 |
| Integration of additional units (up to max.16 units) into an already existent FDA-software licence |
|
Q4 |
Q4 |
| Guarantee extension by 1 year |
|
Q5 |
Q5 |