| Comfort module:
two gas connections with quick release connectors, automatic switch-over of gas cylinders |
|
T1 |
T1 |
T1 |
| Hygiene module:
electropolished interior seamlessly welded by laser |
|
T2 |
T2 |
T2 |
| Communication module:
USB interface, "Celsius" standard software for programming and logging, ring log memory, printer interface |
|
T3 |
T3 |
T3 |
| CO2 module:
extended CO2 range from 0 to 20% |
|
T4 |
T4 |
T4 |
| Premium module:
includes Comfort, Hygiene, Communication and CO2 module |
|
T5 |
T5 |
T5 |
| Humidity-Modul:
active microprocessor control for humidifying and dehumidifying (40-97% rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation; humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile filter; (standard humidity limit control and water dishes are omitted). Can only be ordered together with new incubator (no retrofitting possible) |
|
K7 |
K7 |
K7 |
| Entry port in the rear, heated, with silicone stopper, 57 mm inner diameter |
|
F9 |
F9 |
F9 |
| Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. |
|
H8(x) |
H8(x) |
H8(x) |
| HEPA-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit |
|
H9 |
H9 |
H9 |
| 4-part partitioning of interior with 4-part gas baffle (replacement of 3 full-width by 6 half-width shelves) |
|
- |
- |
K4 |
| Locking door (security lock) |
 |
B6 |
B6 |
B6 |
| Door-hinges on left side |
|
B8 |
B8 |
B8 |
| Extra perforated stainless steel shelf, half width |
|
- |
- |
E6(x) |
| Extra perforated stainless steel shelf, full width |
 |
E7(x) |
E7(x) |
E7(x) |
| Additional stainless steel grid, full width |
 |
E3(x) |
E3(x) |
E3(x) |
| Extra water dish, full width |
 |
E2(x) |
E2(x) |
- |
| Extra water dish, half width |
 |
- |
- |
E2(x) |
| Stacking version for 2 ovens of equal size (bottom oven modification) |
 |
G3 |
G3 |
G3 |
| Subframe 622 mm high |
 |
G5 |
G5 |
G5 |
| Subframe (130 mm high for two stacked cabinets) |
 |
G7 |
G7 |
G7 |
| STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!) |
 |
V9 |
V9 |
V9 |
| Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties |
 |
V1 |
V1 |
V1 |
| Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB |
|
V2 |
V2 |
V2 |
| RS232 interface instead of USB |
|
W6 |
W6 |
W6 |
| Interface Ethernet instead of USB inclusive software "Celsius Ethernet-Edition" |
|
W4 |
W4 |
W4 |
| Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. |
 |
W1 |
W1 |
W1 |
| Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit |
 |
W2 |
W2 |
W2 |
| USB connection cable for computer interface |
 |
W7 |
W7 |
W7 |
| Connection cable for computer interface RS232 according to DIN 12 900-1 |
 |
V6 |
V6 |
V6 |
| Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and CO2 is reached) |
 |
H5 |
H5 |
H5 |
| Potential-free contact (24V/2A) with socket, 3-pin, according to NAMUR NE 28, for combined fault message of temperature and CO2 controller (e.g. supply failure, sensor fault, fuse) |
 |
H6 |
H6 |
H6 |
| Pressure reducing valve to DIN 8546, incl. gas cylinder monitor |
|
H7 |
H7 |
H7 |
| Works calibration certificate for 5%, 7% and 10% CO2 (measured at 37 °C) |
|
Z5 |
Z5 |
Z5 |
| IQ check list with works test data for oven as support for validation by customer |
|
Q1 |
Q1 |
Q1 |
| OQ check list including one free-selectable CO2-, humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 with works test data as support for validation by customer |
|
Q2 |
Q2 |
Q2 |
| Software conforming to FDA "Celsius FDA-Edition" for up to 16 units - only with Communication or Premium module |
|
Q3 |
Q3 |
Q3 |
| Integration of additional units (up to max.16 units) into an already existent FDA-software licence |
|
Q4 |
Q4 |
Q4 |
| Start-up of INCO incubators and brief training (Germany only) through Memmert service. Service not subject to any discount |
|
K9 |
K9 |
K9 |
| Guarantee extension to 3 years |
|
Q5 |
Q5 |
Q5 |