Perfect environmental simulation in the humidity chamber

How to find your order number:

e.g. HCP 153 E7(2) H5
Basic appliance code + Accessories code in any order plus quantity (x) required

Model sizes 108153246
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. H8(x) H8(x) H8(x)
Perforated stainless steel shelf E7(x) E7(x) E7(x)
Stainless Steel Grid E3(x) E3(x) E3(x)
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, left centre/centre F0 F0 F0
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, left centre/top F1 F1 F1
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, right centre/centre F2 F2 F2
Moisture-tight entry port for introducing connections at the side; can be closed from inside by silicone stopper, 23 mm clear diameter, right centre/top F3 F3 F3
Stacking version for 2 ovens of equal size (bottom oven modification) G3 G3 G3
Subframe 622 mm high G5 G5 G5
Subframe (130 mm high for two stacked cabinets) G7 G7 G7
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps V3 V3 V3
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) V4 V4 V4
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising the load!) V9 V9 V9
Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties V1 V1 V1
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface USB V2 V2 V2
RS232 interface instead of USB W6 W6 W6
Interface Ethernet instead of USB inclusive software "Celsius Ethernet-Edition" W4 W4 W4
Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. W1 W1 W1
Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit W2 W2 W2
USB connection cable for computer interface W7 W7 W7
Connection cable for computer interface RS232 according to DIN 12 900-1 V6 V6 V6
Process-dependent electromagnetic door lock D4 D4 D4
Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and rh is reached) H5 H5 H5
Potential-free contact (24V/2A) for combined fault message of temperature and rh controller (e.g. supply failure, sensor fault, fuse) H6 H6 H6
Works calibration certificate for 80% rh (measured at 50 °C) Z5 Z5 Z5
IQ check list with works test data for oven as support for validation by customer Q1 Q1 Q1
OQ check list with works test data for one freely selectable humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 as support for validation by customer Q2 Q2 Q2
Software conforming to FDA "Celsius FDA-Edition" for up to 16 units Q3 Q3 Q3
Integration of additional units (up to max.16 units) into an already existent FDA-software licence Q4 Q4 Q4
Start-up of HCP and brief training (Germany only) through Memmert service. Service not subject to any discount K9 K9 K9