Highly sensitive extremely accurate: Incubator I

How to find your order number:

e.g. INE 500 E0(2) B0
Basic appliance code + Accessories code in any order plus quantity (x) required

Class B

Model sizes 100200300400500    
Perforated stainless steel shelf E0(x) E0(x) E0(x) E0(x) E0(x) - - - -
Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) E2(x) E2(x) E2(x) E2(x) E2(x) - - - -
Stainless Steel Grid E3(x) E3(x) E3(x) E3(x) E3(x) - - - -
Bottom drip tray E8(x) E8(x) E8(x) E8(x) E8(x) - - - -
Wall bracket (tubular frame for wall mounting) G0 G0 G0 G0 G0 - - - -
Stacking version for 2 ovens of equal size (bottom oven modification) G3 G3 G3 G3 G3 - - - -
Subframe adjustable in height (height min. 622 mm) - - - - G5 - - - -
Subframe, but with castors (height 622 mm) - - - - G6 - - - -
Plug-in tube extension straight (l 88 mm, outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) G7 G7 G7 G7 G7 - - - -
Plug-in tube extension angled (outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) G8 G8 G8 G8 G8 - - - -

Class E and P

Model sizes 100200300400500550600700800
Temperature range +300 °C for universal ovens (not available for ovens with glass door) - A0 A0 A0 A0 A0 A0 A0 A0
Adjustable temperature limiter, safety device class 2 instead of adjustable overheat controller safety device class 3.1 - A5 A5 A5 A5 A5 A5 A5 A5
Full-sight glass door (triple-insulating glass) for series UN/UF (extra) - B0 B0 B0 B0 B0 B0 B0 B0
Stainless-steel doors (can be used up to 300 °C) with triple insulating glass window - - - - - - B1 B1 B1
Locking door (security lock) - B6 B6 B6 B6 B6 B6 B6 B6
Door-hinges on left side - B8 B8 B8 B8 B8 - - -
Perforated stainless steel shelf - E0(x) E0(x) E0(x) E0(x) E0(x) E0(x) E0(x) E0(x)
Stainless steel tray (non-perforated), 15 mm rim, (may affect the temperature distribution) - E2(x) E2(x) E2(x) E2(x) E2(x) E2(x) E2(x) E2(x)
Stainless Steel Grid - E3(x) E3(x) E3(x) E3(x) E3(x) E3(x) E3(x) E3(x)
Bottom drip tray - E8(x) E8(x) E8(x) E8(x) E8(x) E8(x) E8(x) E8(x)
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/centre - F0 F0 F0 F0 F0 F0 F0 F0
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, left centre/top - F1 F1 F1 F1 F1 F1 F1 F1
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/centre - F2 F2 F2 F2 F2 F2 F2 F2
Entry port for introducing connections at the side; can be closed by flap, 23 mm clear diameter, right centre/top - F3 F3 F3 F3 F3 F3 F3 F3
Other port 23 mm diameter left - F4(x) F4(x) F4(x) F4(x) F4(x) F4(x) F4(x) F4(x)
Other port 23 mm diameter right - F5(x) F5(x) F5(x) F5(x) F5(x) F5(x) F5(x) F5(x)
Other port 23 mm diameter, in special positions in the back wall (please state location) - F6(x) F6(x) F6(x) F6(x) F6(x) F6(x) F6(x) F6(x)
Other port (38 mm diam.) at the back as per your specification - F7(x) F7(x) F7(x) F7(x) F7(x) F7(x) F7(x) F7(x)
Wall bracket (tubular frame for wall mounting) - G0 G0 G0 G0 G0 G0 G0 -
Flush-fit unit (stainless steel frame covering gap between oven and wall opening) - G1 G1 G1 G1 G1 G1 G1 G1
Stacking version for 2 ovens of equal size (bottom oven modification) - G3 G3 G3 G3 G3 G3 G3 -
Subframe adjustable in height (height min. mm: size 500-600: 622, size 700: 572) - - - - G5 G5 G5 G5 -
Subframe with castors (height: size 500-600: 622 mm, size 700: 572 mm) - - - - G6 G6 G6 G6 -
Interface USB instead of interface RS232 - W3 W3 W3 W3 W3 W3 W3 W3
USB connection cable for computer interface - W7 W7 W7 W7 W7 W7 W7 W7
Connection cable for computer interface RS232 according to DIN 12 900-1 - V6 V6 V6 V6 V6 V6 V6 V6
Fresh-air filter (filtration efficiency 80%) and additional subframe (for sizes 400-700) - - - R8 R8 R8 R8 R8 R8
Flexible Pt100 for positioning in chamber or load with the socket in the front control panel, 4-pin according to NAMUR NE 28 for external temperature recording (load temperature) - H4 H4 H4 H4 H4 H4 H4 H4
Interior lighting (up to size 600: 15 W, size 700/800: 2 x 15 W) - R0 R0 R0 R0 R0 R0 R0 R0
Reinforced chamber - includes replacement of 2 standard shelves by 2 reinforced shelves total height increases by 20 mm (mod. 500 - 700) resp. by 45 mm (mod. 800). - - - - K1 K1 K1 K1 K1
Perforated stainless steel shelf, reinforced for heavy loads (involves reinforced chamber) - - - - E1(x) E1(x) E1(x) E1(x) E1(x)
Interior nearly gastight (UN/IN) - - - K2 K2 K2 - - -
Interior nearly gastight (UN/IN) with possibility for gas inlet/outlet through tube(s) with ball valves - - - K3 K3 K3 - - -
Plug-in tube extension straight (l 88 mm, outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) - G7 G7 G7 G7 G7 G7 G7 G7
Plug-in tube extension angled (outer dia. 40 mm, inner dia. 38 mm), exhaust air ducting (if necessary for connection to extraction system by hose) - G8 G8 G8 G8 G8 G8 G8 G8
Works calibration certificate at three temperatures: 100 °C, 160 °C, 220 °C - Z2 Z2 Z2 Z2 Z2 Z2 Z2 Z2
Works calibration certificate (IN) at three temperatures: 37 °C, 52 °C, 70 °C - Z4 Z4 Z4 Z4 Z4 Z4 Z4 Z4
IQ check list with works test data for oven as support for validation by customer - Q1 Q1 Q1 Q1 Q1 Q1 Q1 Q1
OQ check list including one free-selectable temperature distribution survey to DIN 12880: 2007-05 (size 200/300: 9 measuring points, size 400-800: 27 measuring points) with works test data for oven as support for validation by customer - Q2 Q2 Q2 Q2 Q2 Q2 Q2 Q2

Class P only

Model sizes 100200300400500550600700800
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps - V3 V3 V3 V3 V3 V3 V3 V3
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) - V4 V4 V4 V4 V4 V4 V4 V4
STERICard (additional or as replacement) for automatic incubator chamber sterilisation cycle (not for sterilising the load!) - V9 V9 V9 V9 V9 V9 V9 V9
Oven-linked authorisation card (User-ID-Card) - prevents undesired manipulation by unauthorised third parties - V1 V1 V1 V1 V1 V1 V1 V1
Computer interface RS485 (for networking a maximum of 16 ovens) instead of interface RS232 - V2 V2 V2 V2 V2 V2 V2 V2
Interface Ethernet instead of RS232 inclusive software "Celsius Ethernet-Edition" - W4 W4 W4 W4 W4 W4 W4 W4
Parallel/USB converter cable with integrated power supply unit to connect PCL3-compatible HP printers with USB interface to MEMMERT units. - W1 W1 W1 W1 W1 W1 W1 W1
Documentation package consisting of parallel USB converter cable including PLC3-compatible HP colour inkjet printer with USB interface (HP Deskjet 6980 or successor) for direct connection of printer to Memmert unit - W2 W2 W2 W2 W2 W2 W2 W2
Process-dependent electromagnetic door lock - D4 D4 D4 D4 D4 D4 D4 D4
Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (indication set point reached) - H5 H5 H5 H5 H5 H5 H5 H5
Potential-free contact (24V/2A) for combined fault message (e.g. supply failure, sensor fault, fuse) - H6 H6 H6 H6 H6 H6 H6 H6
Floating triple contact, for signal generation, controlled by programme segment (using PC), for a total of 3 freely selected functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers etc.) - H7 H7 H7 H7 H7 H7 H7 H7
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible) - actual temperature shown on multifunction display, recording in integral ring store and documentation via "Celsius" software or printer. - H8(x) H8(x) H8(x) H8(x) H8(x) H8(x) H8(x) H8(x)
Software conforming to FDA "Celsius FDA-Edition" for up to 16 units - Q3 Q3 Q3 Q3 Q3 Q3 Q3 Q3
Integration of additional units (up to max.16 units) into an already existent FDA-software licence - Q4 Q4 Q4 Q4 Q4 Q4 Q4 Q4