Thanks to the finely tuned control technology, the setpoint temperature in the Memmert climate chamber ICH is exactly reached without any control fluctuations. In combination with the air jacket temperature control, unmatched temperature and humidity homogeneity within the entire interior is guaranteed.
A multifunctional fuzzy controller (P class) with permanent performance adjustments and integrated self-diagnosis system, as well as two high-quality platinum temperature sensors Pt100, ensure absolutely reliable temperature control and the highest process safety and control accuracy for stability tests in the pharmaceutical as well as the food, cosmetics or tobacco industry.
- Temperature range: - 10 °C to + 60 °C (ICH 256), 0 °C to + 60 °C (ICH256L), - 10 °C to + 60 °C (ICH 256C), with a display and adjustment precision of 0.1 °C
- Multiple overtemperature protection: An adjustable undertemperature / overtemperature controller TWW protection class 3.3 (optional adjustable electronic temperature limiter TWB) takes over control at a preset temperature in case of a malfunction. As a special safety feature, we offer an "ASF" integrated overtemperature and undertemperature protection, which automatically monitors the setpoint value at freely selectable intervals. An alarm signal is activated if limits are crossed. The heating is switched off if the maximum value is exceeded and, if the temperature falls below the minimum limit value, the cooling unit is switched off as well. In addition, a mechanical temperature limiter TB permanently switches off heating if the maximum permitted chamber temperature is exceeded by approx. 10 °C.
- 2 high-grade platinum temperature sensors Pt 100 in a 4-wire circuit (for stable long-term transmission of measurement signals) with mutual sensor monitoring and operation transfer at same working temperature
- Digital programme control (programmable to the minute) for profiles consisting of up to 40 ramp segments for temperature, humidity, light (ICH 256L) and CO2 (ICH 256C)
- Weekly timer programmable to the minute
- Fan speed can be adjusted in 10 percent steps
- Simultaneous display of all temperature, weekday, time, speed, humidity, light (ICH 256L), CO2 (ICH 256C) and ramp segment information
- Visual and acoustic alarm if temperature or CO2 content limits are exceeded or if gas bottle is empty (ICH 256C)
- Multi-language (D/UK/E/F/I), alphanumeric text display
- Function signals for stand-by, operating mode, heating and overtemperature / undertemperature
- Internal log memory with 1024kB to save temperature, humidity, light (ICH 256L), CO2 (ICH 256C) and error states with timestamp to the minute
- Chip card control including 1 MEMoryCard XL with 32 kB memory capacity (max. 40 ramps)
- Serial USB interface and Celsius software to control the appliance and read out the appliance's internal log memory.
- Parallel printer interface for printout of log data via an external PCL3 compatible inkjet printer (USB possible using a converter)
Peltier technology, as well as active humidification and dehumidification in the Memmert constant climate chamber are optimally adapted to stability tests according to ICH guidelines and long-term material tests.
Rapid, precise and energy-saving temperature changes along with fast humidity recovery times for controlled environment simulation, climate tests, temperature tests or ageing tests.
The Memmert cooled incubator IPP is ideal for storing protein crystals, due to its low-vibration properties and high-precision temperature control.
Using a Memmert vacuum oven VO, pharmaceutical companies determine the dry content of gel capsules in accordance with standard 731 of the USP (United States Pharmacopeia), and the water content in accordance with USP 921.