Why Memmert

5 good reasons for a Memmert

1 – intuitive operation: touch, turn & go!

Fine glass and stainless steel. The elegant display has characterised Memmert lab ovens for many years now. Since the newest generation of appliances, our products have become intelligent and interactive. Meet the Memmert ControlCOCKPIT!

It has never been easier to operate a lab oven

All adjustable parameters such as temperature (either Celsius or Fahrenheit), relative humidity, fan speed or exhaust air flap position can be set up in three quick steps without getting lost in a complicated menu. During operation all status messages, the current status of heating, ventilation and air flap position as well as time and alarm signals are visible simultaneously.

Intuitive operation of a Memmert oven or incubator

ControlCOCKPIT with touch function available in two model variants: SingleDISPLAY and TwinDISPLAY.
Touch, turn & go. Quick setup in three steps. Never before, a temperature control appliance has been easier to operate.

Intuitive operation of a Memmert oven or incubator

  • ControlCOCKPIT with touch function available in two model variants: SingleDISPLAY and TwinDISPLAY.
  • Touch, turn & go. Quick setup in three steps. Never before has a temperature control appliance been easier to operate.
  • Models with TwinDISPLAY additionally feature setting of device specific parameters and temperature monitoring, graphical display of the program sequence and activation of the optional interior lighting in the right display.
  • Versatile menu functions such as language settings, time zones and daylight saving time as well as the choice between Celsius and Fahrenheit.

2 – stainless steel: precious material offering added value in the lab

For many years, structured stainless steel has been the unmistakable feature of Memmert ovens, incubators and climate chambers in the laboratory. Functional design in its most elegant form: scratch-resistant, hygienic, robust and durable.

Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and can be recycled without any problems.
Stainless steel is the ideal material for temperature control chambers and heating baths. It is particularly corrosion-resistant, hygienic, robust and can be recycled without any problems.

Wherever Memmert ovens and heating baths are used, the superiority of high-quality stainless steel is immediately evident compared to coated sheet steel which can corrode very quickly when in constant use.

For the outer housing of all Memmert appliances, structured stainless steel is used (rear walls are made of galvanised steel sheets).

Stainless steel of class W-St.  1.4301 (ASTM 304) is used for:

  • The inner chamber
  • Sliding shelves, housing
  • Interior basin
  • Accessories for every heating bath

Since aggressive substances are frequently used in the vacuum drying oven, the inner chamber and thermoshelves are made of stainless steel W-St. 1.4404 (ASTM 316L), and the tubing is made of stainless steel W-St. 1.4571 (ASTM 316i).

Innenraum (CO2-Brutschranks optional elektropoliert) und kippgesicherte Einschiebebleche eines Memmert Wärmeschranks sind aus 100% Edelstahl.
Inner chamber (CO2 Incubator, optionally electropolished) and sliding shelves of a Memmert heating oven are made of 100% stainless steel.

Electropolished interior of CO2 incubator ICOmed

The surface roughness of conventional stainless steel can neither be felt with the fingers nor be seen with the bare eyes. However, in some circumstances they can provide a large surface for germs only a few micrometers in length. When working with biological materials, the interior of the CO2 incubator ICOmed can be additionally electropolished. At the same time, the corrosion resistance of the material is increased by this procedure.

3 – Communication: interfaces into the wide world

We think that the programming of a lab oven should be possible from anywhere in the world without problems. For this reason, Memmert devices feature state-of-the-art communication interfaces.

Unlimited communication
Unlimited communication

USB port on the ControlCOCKPIT plus ethernet connection 

An ethernet connection for reading out logs is standard for all new generation Memmert lab -ovens. 

For appliances with TwinDISPLAY, the ethernet connection can be used for:

  • Uploading profiles from the software AtmoCONTROL
  • Profile setup  
  • Online logging  

Appliances with TwinDISPLAY offer a USB port on the ControlCOCKPIT for: 

  • The direct upload of programs
  • Reading out logs  
  • Protecting appliances with individual user-ID function

The individual allocation of IP addresses is possible directly via ControlCOCKPIT.

Interface for programming and log function

  • remote access for reading out logs (SingleDISPLAY) and uploading programs (TwinDISPLAY)
  • all appliances feature a data logger (storage capacity at least 10 years)
  • all appliances with Ethernet interface
  • USB port on appliances with TwinDISPLAY
  • individual allocation of IP addresses possible directly via ControlCOCKPIT

Note about using the software AtmoCONTROL in connection with medical devices

Memmert GmbH + Co. KG clearly labels its devices, which are medical devices per European legislation. The AtmoCONTROL software is not a medical device. All Memmert medical devices can be used for their purpose without the software AtmoCONTROL. AtmoCONTROL is only intended for reading the data logging in conjunction with Memmert GmbH + CO. KG medical devices.

4 – Safety: of users and chamber loads

All Memmert lab ovens feature an electronic temperature monitoring system, a mechanical temperature limiter acc. to DIN 12880 and an integrated auto-diagnostic system with optical and acoustic alarm as a standard.

Even more safety in TwinDISPLAY models

TwinDISPLAY appliances are equipped with an overtemperature monitor as well as two high-grade platinum temperature sensors Pt100 for mutual monitoring and operation transfer at same working temperature in case of an error. Particularly in ramp operation, the integrated temperature monitoring system AutoSAFETY can be activated to automatically follow the set temperature with a freely selectable tolerance. Individual MIN-/MAX-values can be set for over/undertemperature as well as for all other parameters like relative humidity, CO2, O2 and pressure (vacuum).

With the AtmoCONTROL software, alarm notifications can be sent out to an e-mail address. The optional MobileALERT makes it possible to send the alarm notifications by SMS to a mobile phone.

5 – Service: whenever, wherever

The technical service of Memmert has a demanding list of tasks. Supply of spare parts, maintenance, repair and commissioning, IQ/OQ/PQ qualification, customer training and software instruction. It all comes together with global network of service partners that ensures all user queries of Memmert appliances are addressed and fulfilled.

Please don’t hesitate to contact us

If you have questions concerning applications, appliances, quotations, terms or product trainings, you can reach our area managers by phone or by email. Find the contact person for your region under contact / Customer relations international or Sales Force Germany.

If you have questions concerning your orders, please contact our order processing department. Find the contact person for your region under contact / order processing.

If you have questions concerning operation, ordering spare parts, repairs, maintenance contracts, service, guarantees, you can reach our technical service team by telephone, by e-mail or via our contact form. Find your contact partner here.

Overview: Generation 2012