Thank you for registering! On this page, you can find out virtually about Memmert products and service topics. You will receive valuable information for your application from our experts. All webinars are recorded and will be available to you here after broadcast.
Product Launch | m360
In the webinar, Christiane Riefler-Karpa and Philipp Schwarm (Memmert management) as well as Jürgen Grams (Director of m360) and his team presented our new brand and the advantages from which you as a retailer and business partner can greatly benefit from:
Presentation | It's all about the details: Memmert accessories & options
At Memmert, we know that you have specific requirements from our devices as hardly any laboratory or industrial application is identical to the other. Therefore, we offer a wide range of accessories and options to help you achieve precise results. In total, you have the option of configuring 1.2 million device variants, enabling you to design your Memmert device exactly according to your wishes! Our experts will explain how to make the most out of your Memmert device.
Product presentation | Peltier vs. Compressor
Two well-known technologies are used in temperature control units for heating and cooling. The Peltier principle is based on thermoelectric, whereas a compressor uses a refrigerant for cooling. Both offer certain advantages for the customer's individual application. Learn from our experts about the differences and advantages and discover which technology is the right one for your laboratory application.
Presentation | Stability tests according to ICH Q1A (R2)
Prior to a medical product getting approved for the market, products and active ingredients must be tested in accordance with the ICH Q1A standard. This accounts for a wide range of environmental factors. In this way, the shelf life, storage conditions and the re-test time are determined. Stress tests and storage tests also play an important role. Precise control, long-term stability and temperature distribution are important requirements placed on a climate chamber for accelerated, intermediate and long-term tests. With Memmert Advanced Peltier Technology, an energy-efficient solution is created to meet these needs.
Stability tests according to ICH Q1A (R2)
Presentation | Trust the best. Why you should rely on Memmert devices.
Are you fully aware of all the helpful and unique features of the Memmert products? In addition to the obvious advantages of Memmert devices such as the high quality stainless steel, the intuitive operation and the unrivaled design, we offer you several advantages for your daily work relating to security, data and convenient use. Enjoy finding out about the efficiency and practical handling of our products.
Product presentation | Medical Devices and Introduction to the Medical Device Regulation MDR
The Medical Device Directive (MDD) 93/42/EEC will be replaced by the new Medical Device Regulation (EU) 2017/745 as of 26 May 2021. Dr. Stefan Manhart, head of Regulatory Affairs at Memmert, presents the requirements for medical device manufacturers & distributors and provides a wealth of information on medical device consultants. Learn more about Memmert medical devices and the new Medical Device Regulation in your preferred language.
Product presentation | Waterbath WTB accessories
Memmert Waterbaths WTB accessories are compact and have high quality stainless steel build with maximum flexibility and modular concept. Customers find shaking device SV, Peltier-cooling device CDP11, gable cover, test tube rack, flat cover with openings, concentric ring sets and much more easy to accessorize. Convince yourself of the advantages of the waterbath and its accessories in your preferred language.
Product presentation | CO2 incubator ICO/ ICOmed
The ideal breeding process requires temperature consistency and stability as well as optimum relative humidity and CO2 concentration. Thanks to perfectly coordinated systems, the Memmert CO2 incubator ICO/ ICOmed fulfils exactly these requirements and thus promises ideal cell growth. Convince yourself of the advantages of this product in your preferred language.
Product presentation | Vacuum oven VO
The Memmert vacuum oven VO scores not only in terms of energy efficiency, but also dries your load powerfully, turbo fast and yet gently thanks to its intelligent direct heating. Convince yourself of the advantages of this product in your preferred language.
Product presentation | Constant climate chamber HPPeco, Peltier-cooled incubator IPPeco and waterbath WTB
The Peltier-driven appliances, the constant climate chamber HPPeco and the Peltier-cooled incubator IPPeco, work with unrivalled efficiency and also score with excellent performance. The Memmert classic, the waterbath WTB, presents itself with modern comfort features, compact design and maximum flexibility. Convince yourself of the advantages of this product in your preferred language.
Training Global After Sales | Compressor cooling
In order to be able to optimally support users in the handling and maintenance of compressor-cooled Memmert devices, it is important that you, as a service technician, build up expert knowledge on this subject. This webinar will train you in the topics principle of compressor cooling, explanation of the cooling circuit, measurement at reference points and the unique features of our cooling unit.
Training Global After Sales | Humidity controlling
In this training, you will get useful hints from our Global After Sales experts about humidity controlling of a Memmert product, such as the optimal water quality, the difference between active and passive humidification systems, basic functions of the humidity board and much more.
Training Global After Sales | General troubleshooting
When developing and manufacturing our climate and temperature control chambers, we take great care to ensure quality and reliability. Special attention is paid to the longevity of our products. This enables users to work with their Memmert devices for many years without restrictions. The Global After Sales Team is always available for questions, maintenance, calibrations and more. Our experts will explain to you how to check error messages, read circuit diagrams, measure the voltage at reference points and much more.
Training Global After Sales | Vacuum oven VO
The Memmert Vacuum oven VO has long been a leader among such technology. The careful servicing makes sure it stays that way. Our servicing team shows you information on its thermoshelves, calibration, maintenance parts, door seal, and adjusting and replacing doors and more in a practical demonstration.
Training Global After Sales | Humidity Controlling
Knowing about Memmert humidity control become crucial for any servicing job. This service webinar teaches the difference between active and passive dehumidification systems, perfect water quality and comparison of the old and new steam generator system. Later, you will learn about the principle function of the humidity board, status indication of LEDs, measuring at reference points, functional test of the water pump and replacement of water filters. Later, you will find a practical explanation as well.
Training Global After Sales | Software AtmoCONTROL
You are already familiar with the user friendly, intuitive, user interface of the Memmert AtmoCONTROL. This service webinar shows how to set the network connection, function differences between the SingleDISPLAY and TwinDISPLAY units, creation of profiles via USB and internet, profile simulation, reading and sending protocol data, transfer of device license, firmware update and more in a hands-on demonstration.
Training Global After Sales | CO2 incubator ICO & humidity chamber HCP
The Memmert CO2 incubator ICO and Humidity chamber HCP service webinar will help learn: differences with standard units, access to electronics via shutterbox and the rear side, handling error messages, maintenance parts, adjusting and replacing doors, replacing seals and more in a practical demonstration!
Training Global After Sales | Constant climate chamber HPPeco and Peltier-cooled incubator IPPeco
This service webinar is all about the HPPeco and IPPeco devices. You learn about available documents and the Peltier elements present in Memmert devices. Energy efficiency is at the heart of Advanced Peltier Technology. You come to find out about required tools, electronic components, functional test and replacement of Peltier elements and fan motors, replacement of dehumidification of Peltier elements and introduction of steam generator and more in a practical explanation.
Training Global After Sales | Waterbath WTB
The Memmert Waterbath WTB is known for its high quality stainless steel built, ergonomic design and state of the art technology. In this service webinar, you learn about the servicing documentation, its build and improved drain system, electronic and heating system, necessary tools and more later in a practical overview.
Training Global After Sales | Basic I - Mechanics
This basic mechanics service webinar looks into some key areas for the user. The first aspect deals with cover, side panels, rear panels, shutterbox, retrofitting a stacking version and renewal of the chamber seal. The final part shows adjustment of outer and inner glass doors, replacement of door lock mechanism and door handle, door hinge position adjustment and the renewal of the door seal. Afterwards, there’s a practical demonstration.
Training Global After Sales | Basic II - Electronics
Following up on our service webinar on basic mechanics, you now learn more about the basic electronics of Memmert devices. This webinar discusses error messages, general trouble shooting, measurement of voltage and current on reference points and replacement of electronic components. These are ControlCOCKPIT, power board, sensors, temperature limiter and the fan motors. A practical demonstration is provided as well.
Training Global After Sales | Peltier technology
Memmert perfected Peltier technology has been leading the market for decades. Our high quality, energy saving Peltier devices continue to reach new heights. In this service webinar, you learn about its functional principle, thermal and electric functional tests, replacement of temperature elements and fan motors. And finally, the replacement of the dehumidification system is also explained, among others, in a practical demonstration.