The heating oven Um is a Class I medical device.

Universal oven heating and drying with natural air circulation (convection) TwinDISPLAY UN110plus 745 x 864 x 584 mm
Classified medical device

Intended use for heating and keeping warm as a medical device
Universal heating oven Um

Memmert heating ovens Um or Umplus may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. Memmert is bringing medical devices of class I according to the regulation MDR (EU) 2017/745 into circulation.

Safety – combined with optimum operating comfort

The touch screen of the Memmert heating oven is easy and intuitive to use and, even when used intensively, our heating oven made of high-quality stainless steel never loses its shine or reliability. Choose the heating oven ideally suited to your needs from 34 models expandable with convenient special accessories. The cutting-edge control technology of the TwinDISPLAY model version leaves nothing to be desired in terms of thermal safety, precision and quality assurance.

A Memmert heating oven/drying oven offers unique advantages

  • intuitive and easy-to-use operating menu
  • air exchange rates and air flap position electronically controllable
  • temperature and air exchange ramps programmable via AtmoControl software (models with TwinDISPLAY)
  • pre-heated fresh air prevents temperature fluctuations
  • almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • heating concept specifically adapted for a precise and homogenous temperature control
  • a wide range of options for reading the data logging using interfaces, integrated data logger and Software AtmoCONTROL
  • 3 years guarantee worldwide

Standard units are safety-approved and bear the test marks

CE
VDE
UL

Models

Size
Air Circulation
Performance Class
Show more
SingleDISPLAY SingleDISPLAY for basic applications Temperature, air flap and fan remain unchanged during the whole process
Show more
TwinDISPLAY TwinDISPLAY Maximum comfort for complex processes For many years to come the equipment of Memmert's model variant TwinDISPLAY will leave nothing to be desired regarding function range, convenience and safety.
Description Air Circulation Performance Class
UN30m UN30m Natural air circulation (Convection) SingleDISPLAY Details
UN30mplus UN30mplus Natural air circulation (Convection) TwinDISPLAY Details
UF30m UF30m Forced air circulation (Fan) SingleDISPLAY Details
UF30mplus UF30mplus Forced air circulation (Fan) TwinDISPLAY Details
UN55m UN55m Natural air circulation (Convection) SingleDISPLAY Details
UN55mplus UN55mplus Natural air circulation (Convection) TwinDISPLAY Details
UF55m UF55m Forced air circulation (Fan) SingleDISPLAY Details
UF55mplus UF55mplus Forced air circulation (Fan) TwinDISPLAY Details
UN75m UN75m Natural air circulation (Convection) SingleDISPLAY Details
UN75mplus UN75mplus Natural air circulation (Convection) TwinDISPLAY Details
UF75m UF75m Forced air circulation (Fan) SingleDISPLAY Details
UF75mplus UF75mplus Forced air circulation (Fan) TwinDISPLAY Details
UN110m UN110m Natural air circulation (Convection) SingleDISPLAY Details
UN110mplus UN110mplus Natural air circulation (Convection) TwinDISPLAY Details
UF110m UF110m Forced air circulation (Fan) SingleDISPLAY Details
UF110mplus UF110mplus Forced air circulation (Fan) TwinDISPLAY Details
UN160m UN160m Natural air circulation (Convection) SingleDISPLAY Details
UN160mplus UN160mplus Natural air circulation (Convection) TwinDISPLAY Details
UF160m UF160m Forced air circulation (Fan) SingleDISPLAY Details
UF160mplus UF160mplus Forced air circulation (Fan) TwinDISPLAY Details
UN260m UN260m Natural air circulation (Convection) SingleDISPLAY Details
UN260mplus UN260mplus Natural air circulation (Convection) TwinDISPLAY Details
UF260m UF260m Forced air circulation (Fan) SingleDISPLAY Details
UF260mplus UF260mplus Forced air circulation (Fan) TwinDISPLAY Details
UN450m UN450m Natural air circulation (Convection) SingleDISPLAY Details
UN450mplus UN450mplus Natural air circulation (Convection) TwinDISPLAY Details
UF450m UF450m Forced air circulation (Fan) SingleDISPLAY Details
UF450mplus UF450mplus Forced air circulation (Fan) TwinDISPLAY Details
UN750m UN750m Natural air circulation (Convection) SingleDISPLAY Details
UN750mplus UN750mplus Natural air circulation (Convection) TwinDISPLAY Details
UF750m UF750m Forced air circulation (Fan) SingleDISPLAY Details
UF750mplus UF750mplus Forced air circulation (Fan) TwinDISPLAY Details
UF1060m UF1060m Forced air circulation (Fan) SingleDISPLAY Details
UF1060mplus UF1060mplus Forced air circulation (Fan) TwinDISPLAY Details

Intended use as medical device

Memmert is bringing medical devices of class I according to EU Directive (EU) 2017/745 into circulation.

Type Intended use as medical device Classification according to (EU) 2017/745
UNmplus, UFmplus The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
UNm, UFm, INm, IFm The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
INmplus, IFmplus Im may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. Implus may be used for temperature control of rinsing and infusion solutions and contrast agents. I
IFbw The appliance is used to heat non-sterile cloths and covers. Any other use is improper
and may cause damage or danger.
I

Memmert is bringing medical devices of class IIa and IIb into circulation according to MDD 93/42/EEC until 31.12.2028 according to the transitional provisions (EU) 2023/607 by the (EU) 2017/745 article 120 (2).

Type Intended use as medical device Classification according to 93/42/EWG
SNplus, SFplus The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
SN, SF The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
ICOmed The CO2 incubator ICOmed is used to generate and maintain constant ambient conditions for the in-vitro fertilisation (IVF) application field, especially for the incubation of oocytes, spermatozoa and zygotes in special culture dishes for IVF application as well as for gene expression and the biosynthesis of RNA and proteins. IIa

Download as pdf

Medical device consultant training

As part of our medical device consultant training, we qualify you in the consultation, use and instruction of our medical products, taking into account the currently applicable legal requirements with regard to the new Medical Devices Regulation (EU) 2017/745. We explain the requirements for dealers, the geographical scope as well as information on the reporting system and the tasks of a medical device consultant. After successful participation, you will receive a certificate of qualification as a medical device consultant for Memmert medical devices.

Have we piqued your interest? Please contact us at sales@memmert.com for more information.