|
Voltage 115 V, 50/60 Hz (no extra cost) |
X2 |
X2 |
X2 |
X2 |
X2 |
X2 |
|
|
|
|
Extended overtemperature protection by additionally integrated Pt100 sensor for independent temperature monitoring for models with SingleDISPLAY |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
A6 |
|
Temperature restriction - Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +250 °C (Please, indicate upon ordering) |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
A8 |
|
Full-sight glass door (4-layer insulating glass), temperature range up to max. +250 °C (requires option A8 against surcharge) |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
B0 |
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 300 °C. |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
B1 |
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (standard with 1060) |
|
|
|
|
|
|
K1 |
K1 |
|
|
Interior lighting for observing the load |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
R0 |
|
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
|
Interior nearly gastight - technical clarification required for combination with other options |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
K2 |
|
Interior nearly gastight with possibility for inlet/outlet through 2 tubes with ball valves - technical clarification required for combination with other options |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
K3 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
F2 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
F3 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
|
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
F6 |
|
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
D6 |
|
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
F7 |
|
Entry port, 57 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 30-75) |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
F8 |
|
Entry port, 100 mm clear diameter, can be closed by flap, in special positions at the back (please, state location; not possible for UF/UFplus/UFm/UFmplus size 75) |
|
|
F9 |
F9 |
F9 |
F9 |
F9 |
F9 |
F9 |
|
4 – 20 mA current loop interface (0 to +310°C corresponds to 4 – 20 mA), temperature controller actual value |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
|
4 – 20 mA current loop interface (0 to +310 °C corresponds to 4 – 20 mA), temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY, max. 3 TwinDISPLAY) |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
|
Fan speed monitoring with switching off the heating and with alarm in case of failure – optional for UFplus only |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
|
Door with lock and key (safety lock) |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
|
Door hinged on the left |
B8 |
B8 |
B8 |
B8 |
B8 |
B8 |
|
|
|
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
|
Process-dependent programmable door lock (only for units with TwinDISPLAY) |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
|
Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
|
Castor frame (2-part), height 140 mm |
R9 |
R9 |
R9 |
R9 |
R9 |
R9 |
|
|
|
|
Fresh-air filter (filtration efficiency 80 %) mounted at the bottom (for UF/UFplus). For model sizes 30 – 260, subframe or subframe on castors obligatory |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |
R8 |