Steriliser S

Sterilisation done without requiring disinfection of laboratory instruments and equipment. A hot air sterilisation device protects and saves lives in medicine.

Hot air sterilizer with natural air circulation (convection) TwinDISPLAY SN110plus 745 x 864 x 584 mm
Medical Device CE 0197

To ensure laboratory equipment and devices are sterilized
Hot air Steriliser S

What is hot air sterilisation? Steriliser S makes use of dry sterilisation to ensure laboratory equipment and devices are sterilized. With this method, hot air, devoid of water vapor or moisture, makes sure the device is sterile without needing risk prone disinfection methods. Each Memmert hot air steriliser S is classified as class IIb medical device. Memmert is bringing medical devices of class IIb into circulation according to MDD 93/42/EEC until 26 May 2024 according to the transitional provisions by the (EU) 2017/745 article 120 (2).
  • Hot air sterilisation temperature range up to +250 °C
  • 8 model sizes (32 to 749 liters volume) to heat sterilize as needed
  • 2 model variants: SingleDISPLAY and TwinDISPLAY
  • Natural convection or forced air circulation N/F

Advantages of using hot air sterilisation in Steriliser S

  • Intuitive and user friendly operating menu
  • SetpointWAIT function ensures that the program is only continued when the setpoint hot air sterilisation temperature is reached
  • Optional process-controlled, electromagnetic door lock (models with TwinDISPLAY)
  • User-ID function prevents manipulation in hot air sterilisers like Steriliser S
  • Almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • heating concept specifically adapted for a precise and homogenous temperature control
  • a wide range of options for reading the data logging using interfaces, integrated data logger and Software AtmoCONTROL
  • 3 years guarantee worldwide

Importance of hot air sterilisation

  • Disinfection of appliances and instruments is not sufficient in medicine and research. Only hot air sterilisation provides sufficient protection.
  • Precisely maintaining the heat sterilisation time and the termination of even the most resistant microorganisms. These are guaranteed at all times, irrespective of the hot air sterilisation load and chamber volume.
  • For the special application of depyrogenisation, the hot air Steriliser S is absolutely ideal as an example of hot air sterilisation.

Standard units are safety-approved and bear the test marks

CE LGA
VDE
UL

Models

Size
Performance Class
Show more
SingleDISPLAY SingleDISPLAY for basic applications Temperature, air flap and fan remain unchanged during the whole process
Show more
TwinDISPLAY TwinDISPLAY Maximum comfort for complex processes For many years to come the equipment of Memmert's model variant TwinDISPLAY will leave nothing to be desired regarding function range, convenience and safety.
Air Circulation
Description Performance Class Air Circulation
SN30 SN30 SingleDISPLAY Natural air circulation (Convection) Details
SN30plus SN30plus TwinDISPLAY Natural air circulation (Convection) Details
SF30 SF30 SingleDISPLAY Forced air circulation (Fan) Details
SF30plus SF30plus TwinDISPLAY Forced air circulation (Fan) Details
SN55 SN55 SingleDISPLAY Natural air circulation (Convection) Details
SN55plus SN55plus TwinDISPLAY Natural air circulation (Convection) Details
SF55 SF55 SingleDISPLAY Forced air circulation (Fan) Details
SF55plus SF55plus TwinDISPLAY Forced air circulation (Fan) Details
SN75 SN75 SingleDISPLAY Natural air circulation (Convection) Details
SN75plus SN75plus TwinDISPLAY Natural air circulation (Convection) Details
SF75 SF75 SingleDISPLAY Forced air circulation (Fan) Details
SF75plus SF75plus TwinDISPLAY Forced air circulation (Fan) Details
SN110 SN110 SingleDISPLAY Natural air circulation (Convection) Details
SN110plus SN110plus TwinDISPLAY Natural air circulation (Convection) Details
SF110 SF110 SingleDISPLAY Forced air circulation (Fan) Details
SF110plus SF110plus TwinDISPLAY Forced air circulation (Fan) Details
SN160 SN160 SingleDISPLAY Natural air circulation (Convection) Details
SN160plus SN160plus TwinDISPLAY Natural air circulation (Convection) Details
SF160 SF160 SingleDISPLAY Forced air circulation (Fan) Details
SF160plus SF160plus TwinDISPLAY Forced air circulation (Fan) Details
SN260 SN260 SingleDISPLAY Natural air circulation (Convection) Details
SN260plus SN260plus TwinDISPLAY Natural air circulation (Convection) Details
SF260 SF260 SingleDISPLAY Forced air circulation (Fan) Details
SF260plus SF260plus TwinDISPLAY Forced air circulation (Fan) Details
SN450 SN450 SingleDISPLAY Natural air circulation (Convection) Details
SN450plus SN450plus TwinDISPLAY Natural air circulation (Convection) Details
SF450 SF450 SingleDISPLAY Forced air circulation (Fan) Details
SF450plus SF450plus TwinDISPLAY Forced air circulation (Fan) Details
SN750 SN750 SingleDISPLAY Natural air circulation (Convection) Details
SN750plus SN750plus TwinDISPLAY Natural air circulation (Convection) Details
SF750 SF750 SingleDISPLAY Forced air circulation (Fan) Details
SF750plus SF750plus TwinDISPLAY Forced air circulation (Fan) Details

Intended use as medical device

Memmert is bringing medical devices of class I according to EU Directive 93/42/EEC into circulation until the regulation MDR (EU) 2017/745 comes into force. After the new regulation comes into force, Memmert will bring medical devices of class I into circulation according to MDR.

Type Intended use as medical device Classification according to MDD
UNmplus, UFmplus The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
UNm, UFm, INm, IFm The appliance may be used for heating fango, silicate and APS packs for physical therapy and keeping them warm. I
INmplus, IFmplus The appliance may be used for temperature control of rinsing and infusion solutions and contrast agents. I
IFbw The appliance may be used for heating non-sterile covers and cloths. I

Memmert is bringing medical devices of class IIa and IIb into circulation according to MDD 93/42/EEC until 26 May 2024 according to the transitional provisions by the (EU) 2017/745 article 120 (2).

Type Intended use as medical device Classification according to MDD
SNplus, SFplus The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
SN, SF The product is intended for the sterilisation of medical devices with dry heat at atmospheric pressure. IIb
ICOmed The appliance is intended for the creation and maintenance of constant environmental conditions for application in the field of in vitro fertilisation (IVF), especially for the incubation of oocytes, spermatozoa and zygotes in special culture dishes for IVF application as well as for gene expression and the biosynthesis of RNA and proteins. IIa

Download as pdf

Medical device consultant training

As part of our medical device consultant training, we qualify you in the consultation, use and instruction of our medical products, taking into account the currently applicable legal requirements with regard to the new Medical Devices Regulation (EU) 2017/745. We explain the requirements for dealers, the geographical scope as well as information on the reporting system and the tasks of a medical device consultant. After successful participation, you will receive a certificate of qualification as a medical device consultant for Memmert medical devices.

Have we piqued your interest? Please contact us at sales@memmert.com for more information.