In over 190 countries all over the world, hundreds of thousands of Memmert products have been permanently in use for decades. This is why Memmert is one of the leading suppliers of temperature control appliances worldwide.
Let us take you into the fascinating world of Memmert appliances, which we have collected.
Molecular gastronomy is renowned for using laboratory equipment to create completely new dishes, flavours and textures. Copenhagen’s Alchemist is one of the top international restaurants to have applied this experimental approach as part of a unique culinary signature. In its kitchens, this innovative Danish venue has two Memmert incubators for fermenting ingredients.
¿Almacenar las sondas de alta sensibilidad en una cámara climática con una fluctuación de temperatura máxima de 0,2 K? ¿Acortar los tiempos de secado al vacío? ¿Garantizar la seguridad de las pruebas continuas a largo plazo? ¿Llevar a cabo ensayos con tasas de intercambio de aire definidas? En nuestra página de aplicaciones "Industria" presentamos nuestros equipos Memmert y sus aplicaciones.
El enfoque intransigente en cuanto a calidad ha permitido que Memmert sea, desde los comienzos allá por el año 1947, un socio fiable de la medicina así como de la investigación médica. Por supuesto, Memmert posee la certificación DIN EN ISO 13485 para los dispositivos médicos. Memmert ha superado satisfactoriamente la prórroga de los certificados MDD 93/42/CEE. El organismo designado ha vuelto a expedir el certificado CE existente, la Directiva 93/42/CEE, y ahora es aplicable hasta mayo de 2024 de conformidad con la disposición transitoria (UE) 2017/745. Esta aplicación especial en torno al tema de la medicina muestra los equipos y aplicaciones adecuados.
Es la pasión por el detalle lo que determina la calidad extraordinaria de nuestros equipos con regulación de temperatura. Es el enfoque basado en las necesidades de nuestros usuarios lo que hace que los equipos Memmert sean los acompañantes habituales desde hace décadas de laboratorios farmacéuticos y para la investigación médica. En esta página encontrará estudios de casos y equipos.
Estamos comprometidos en cuerpo y alma con el buen gusto. Para garantizar la extraordinaria fiabilidad y precisión de los incubadores, las estufas de calentamiento y las cámaras climáticas de Memmert, desarrollamos y fabricamos todas las piezas importantes nosotros mismos. Aquí puede leer más sobre lo que tenemos que ofrecerle a la industria alimentaria.
Greg LeMond, Mark Cavendish, Normann Stadler and Faris Al-Sultan are only a few of the thousands of athletes who have monitored their performance with the help of an SRM PowerMeter during their athletic careers. The highly sensitive strain sensors in the interior of the device enable precision and measurement accuracy. The hardening of the strain gauges is performed in three Memmert drying ovens.
In the year 1987, the German engineer and cyclist enthusiast Ulrich Schoberer registered a patent for his PowerMeter. Elite race cyclists, triathletes and mountain bikers had long awaited a mobile performance measurement device with such high reliability and precision that enabled real-time evaluation of their current form. What followed was a product evolution: high precision, light and robust materials, adaptation for bottom bracket sets of all leading manufacturers and wireless data transmission. The integration of additional real-time data like heart rate, distance covered, speed and altitude enable the modern athlete to optimise training and competition on-the-fly, so to speak. The idea behind this is simple but ingenious, like any other great invention.
Until now, in most cases heart rate was used as a performance indicator. However, fatigue and the weather can falsify physiological values. For Schoberer, pedal power seemed like the most objective indicator of a cyclist's performance. For this reason, he invented a device which measures the power at the point where the two pedal forces intersect, before the force is transmitted to the chain and rear wheel: at the crank spider between the inside bearing axle and chainrings. In addition to monitoring performance, athletes can also use the PowerMeter to test their aerodynamics and try different seating positions for optimum power transmission to the pedals.
Pedal power is measured with conductors on a foil, so-called strain gauges, which are placed on the crank spider with utmost care. High-end models feature up to 16 strips (8 carriers with two individual grids each). With every pedalling movement, the strips are stretched and the electrical resistance changes. The PowerMeter converts the resulting voltage change into a frequency proportional to the torque. Based on the simultaneously measured angular speed (pedalling frequency), the PowerControl calculates the pedal power in watts. The athletes can check their power in real time, as an instantaneous, average or maximum value in the PowerControl display and save it in adjustable intervals. After the assembly of the electronic components, which is also done manually, each PowerMeter device is calibrated using standard weights to guarantee a measurement accuracy with a deviation of less than 1 % for the entire performance range of an athlete.
The highly sensitive strain gauges are the core of the SRM PowerMeter because what counts for the athletes in the end is measurement accuracy. Alongside the manual assembly, the controlled drying of the strain gauges after gluing are a decisive quality factor. Due in particular to the excellent performance regarding temperature distribution and stability, SRM decided to purchase three Memmert drying ovens for their headquarters in Jülich and their production site in Colorado. "As in microbiology, precision and reliability are the most important things for what we are doing", says Markus Biewer, responsible for quality assurance at SRM. Each night, glued parts are put in the drying oven and a defined process runs until the morning, starting with the warming up and hardening of the strain gauges at 135 °C until the cooling phase.
AtmoSAFE would like to thank SRM GmbH, in particular Mr Biewer, for the kind support during the preparation of this article.