In over 190 countries all over the world, hundreds of thousands of Memmert products have been permanently in use for decades. This is why Memmert is one of the leading suppliers of temperature control appliances worldwide.
¿Almacenar las sondas de alta sensibilidad en una cámara climática con una fluctuación de temperatura máxima de 0,2 K? ¿Acortar los tiempos de secado al vacío? ¿Garantizar la seguridad de las pruebas continuas a largo plazo? ¿Llevar a cabo ensayos con tasas de intercambio de aire definidas? En nuestra página de aplicaciones "Industria" presentamos nuestros equipos Memmert y sus aplicaciones.
El enfoque intransigente en cuanto a calidad ha permitido que Memmert sea, desde los comienzos allá por el año 1947, un socio fiable de la medicina así como de la investigación médica. Por supuesto, Memmert posee la certificación DIN EN ISO 13485 para los dispositivos médicos. Memmert ha superado satisfactoriamente la prórroga de los certificados MDD 93/42/CEE. El organismo designado ha vuelto a expedir el certificado CE existente, la Directiva 93/42/CEE, y ahora es aplicable hasta mayo de 2024 de conformidad con la disposición transitoria (UE) 2017/745. Esta aplicación especial en torno al tema de la medicina muestra los equipos y aplicaciones adecuados.
Es la pasión por el detalle lo que determina la calidad extraordinaria de nuestros equipos con regulación de temperatura. Es el enfoque basado en las necesidades de nuestros usuarios lo que hace que los equipos Memmert sean los acompañantes habituales desde hace décadas de laboratorios farmacéuticos y para la investigación médica. En esta página encontrará estudios de casos y equipos.
Estamos comprometidos en cuerpo y alma con el buen gusto. Para garantizar la extraordinaria fiabilidad y precisión de los incubadores, las estufas de calentamiento y las cámaras climáticas de Memmert, desarrollamos y fabricamos todas las piezas importantes nosotros mismos. Aquí puede leer más sobre lo que tenemos que ofrecerle a la industria alimentaria.
Let us take you into the fascinating world of Memmert appliances, which we have collected on our user platform.
Molecular gastronomy is renowned for using laboratory equipment to create completely new dishes, flavours and textures. Copenhagen’s Alchemist is one of the top international restaurants to have applied this experimental approach as part of a unique culinary signature. In its kitchens, this innovative Danish venue has two Memmert incubators for fermenting ingredients.
The history of microbiology and the development of associated methods starts with Robert Koch. Today, AtmoSAFE will take you on a journey from temperature control in gas-heated incubators to the invention and patentation of mechanical temperature control by Willi Memmert.
The second half of the 19th century was an exciting time for science. Max von Pettenkofer, Rudolf Virchow, Robert Koch and Louis Pasteur - to just name a few - were all ground-breaking pioneers in the field of etiology and the development of hygiene standards. The Charité in Berlin, the Robert Koch Institute and the Pasteur Institute established their worldwide reputation.
Particularly Robert Koch, who - besides Louis Pasteur - is considered to be the father of microbiology, passionately devoted himself to the development of microbiological methods. He replaced the broth that had previously been used as a breeding medium for germ cultivation by solid and transparent media containing gelatin. Furthermore, his research also paved the way for the perfection of the incubator.
At that time, the Berlin-based company Lautenschläger was the leading manufacturer of laboratory equipment. Incubators were always operated at a constant temperature, since temperature control at different temperatures was not yet possible. The "thermostats” were insulated with asbestos or linoleum, heat transfer to the interior was provided through a water jacket, heating was done using gas and even double doors, the interior ones made of glass, were already a matter of course. Calibration of the temperature controller, however, was significantly more difficult than today. Lautenschläger’s “thermo regulator” (fig. 2) consisted of a glas tube [G] closed at the bottom end around which the water of the incubator’s water jacket could circulate, a space for regulation [R], an adjustable metal tube [Z] and a glass spiral [S] filled with mercury at the bottom end of the glas tube. The gas was introduced at [B] and discharged at [A]. As mercury expands in direct proportion to the temperature, it rose in the glas tube at increasing temperatures, closed the opening [U] of the inlet tube [Z], so that gas could only be introduced in small amounts through a side tube. If the temperature fell below the desired set temperature, this caused the mercury level to sink and the the main gas tube was opened for reheating. “Calibration” of the temperature control was done in advance in a waterbath with a slightly higher temperature than the desired constant temperature in the incubator. The inlet tube [Z] was pushed downwards until the gas flame just began to shrink. The water jacket of the incubator was filled with water at the set temperature. Afterwards, the regulator was introduced into the water in the incubator and connected to the gas supply.
It was an exciting time for Willi Memmert when he delivered his first hot air steriliser in 1947. The development of the “Aeolus” marked the beginning of a new passion for the company founder of Memmert – the very passion that had already motivated Robert Koch still prevails at Memmert today: the quest for uniform temperature distribution in the working chamber of an incubator, hot air steriliser or drying oven. Willi Memmert achieved this with ease and had his ground-breaking invention patented in the early 50s already. Until the early 90s, when Memmert as one of the first companies worldwide developed and deployed a PID process controller for temperature regulation, this principle of his mechanical temperature controller guaranteed unique precision.
The greatest inventions are often brilliantly simple. Willi Memmert used the fact that metal surfaces – and also the interior of an incubator or drying oven - expand due to heat. He installed a heated plate in the back of his appliances, connected to a control rod with a higher heat resistance. If the plate expanded due to the heat, the control rod moved upwards, two contacts installed on a seesaw engaged and a relay was triggered, disconnecting the power supply for the heating unit. This way, the incubator or drying oven was used as a control element itself. The way from heating unit to the controller was minimised, and the disadvantages of control delay or inaccuracy as a result of temperature sensors in the working chamber, common until then, were overcome
Thanks to a control knob filed for patent by Willi Memmert when adjustable incubators, sterilisers and drying ovens were introduced, it was possible to exactly adjust the temperature with a precision of less than ± 0.5 °C. Competitors' appliances generally used printed or engraved scales. The disadvantages were obvious: Back then, each appliance was subject to manufacturer tolerances and a fixed temperature scale made it impossible to calibrate it later on. It has always been Memmert’s company philosophy never to save money at the expense of precision in manufacturing. This way, each Memmert appliance was individually calibrated by hand until the introduction of digital control technology. The temperature in the working chamber was measured and then marked on the knob at the corresponding scale position.
However, temperature control only accounted for half the precision of Memmert’s incubators, hot air sterilizers and drying ovens. The other half can be attributed to the unique heating concept. In the early 50s, the appliance walls had been equipped with hollows for heating element integration already. These hollows enlarged the surface for heat transfer and additionally made it possible to place shelves on them. The third decisive advantage was the uniform heat distribution from all sides of the interior.
The will to continuously increase his knowledge made Willi Memmert a pioneer in temperature control technology and Memmert the technological leader for temperature control appliances. If you are interested in finding more answers on the question why Memmert incubators, hot air sterilisers and ovens are still of unparalleled precision today, have a look at the Memmert homepage.