Options / Accessories

para Incubador de CO2

Seguridad en todo momento: Funciones superiores para proteger cultivos de células, de bacterias o de tejidos.

Opciones

Tamaños de modelos 50 105 150 240
4 – 20 mA current loop interface O2 controller, actual value (0 – 25 % O2 4 – 20 mA) V1 V1 V1 V1
4 – 20 mA current loop interface CO2 controller, actual value (0 – 25 % CO2 4 – 20 mA) V9 V9 V9 V9
4 – 20 mA current loop interface Humidity controller, actual value (0 – 100 % rh 4 – 20 mA) V7 V7 V7 V7
Start-up of ICOmed incubators and brief training (D, A, CH only), through Memmert service, not subject to discount K9 K9 K9 K9
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37 °C) special works calibration certificates upon request D00106 D00106 D00106 D00106
4 – 20 mA current loop interface Temperature controller, actual value (0 to +70 °C 4 – 20 mA) V3 V3 V3 V3
Inner door with partitioned glass doors K4 K4 K4
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back, centre right; not available for ICO50med with active humidity control (option K7) or humidity display (option K6) F7 F7 F7 F7
Capacitive humidity sensor for measuring and displaying the relative humidity K6 K6 K6 K6
Peltier cooling unit enables a working temperature of 37 °C even at higher ambient temperatures of up to 35 °C K5 K5 K5 K5
Control of oxygen concentration by N2 inlet; adjustment range 1 % up to 20 % O2; setting accuracy 0.1 % (requires option K7) T6 T6 T6 T6
Active microprocessor control for humidifying and dehumidifying (40 – 97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation. Humidity supply with distilled water (from an external tank) by a self-priming pump; integral bacteria block by generating hotsteam, dehumidifying via sterile filter K7 K7 K7 K7
Electropolished interior T2 T2 T2 T2
MobileALERT for up to 4 alarm notifications; standard: temperature and CO2 alarm, additionally humidity alarm (when equipped with option K7) and O2 alarm (when equipped with option T6) C4 C4 C4 C4
Battery-buffered ControlCOCKPIT. Uninterrupted supply for the entire display unit (ControlCOCKPIT) and therefore complete documentation of all parameteres even when there is a power failure. The CO2 parameter is continously regulated. C2 C2 C2 C2
Voltaje115 V, 50/60 Hz (sin coste adicional) X2 X2 X2 X2
Módulo Confort: dos conexiones de gas con acoplamiento rápido, y cambio automático de botella de gas T1 T1 T1 T1
Contacto sin potencial (24 V/2 A) con borne incorporado
conforme a NAMUR NE 28 para control externo
(valores nominales de temperatura y CO<sub>2</sub> alcanzados) Contacto sin potencial (24 V/2 A) con borne incorporado conforme a NAMUR NE 28 para control externo (valores nominales de temperatura y CO2 alcanzados) H5 H5 H5 H5
Puerta montada a la izquierda B8 B8 B8 B8
Contacto sin potencial (24 V/2 A) con borne incorporado conforme a NAMUR NE 28 para mensajes de error (ALARMA, p. ej., en caso de corte de corriente, fallo de sensores o fusibles) Contacto sin potencial (24 V/2 A) con borne incorporado conforme a NAMUR NE 28 para mensajes de error (ALARMA, p. ej., en caso de corte de corriente, fallo de sensores o fusibles) H6 H6 H6 H6
MobileALERT: notificaciones de alarma a través de un mensaje de texto (SMS) de todo tipo de aviso de alarma o error del equipo. Condición: opción H6 de «contacto sin potencial para avisos de error» C3 C3 C3 C3

Accesorios

Tamaños de modelos 50 105 150 240
Kit de apilado (compuesto de esquinas de apilado, una placa de conexión para la parte posterior, dos soportes de pared) para apilar 2 unidades de ICO150med e ICO240med B42114 B42115
HEPA-filter for chamber (filter class E11) according to EN 1822, packed in sterile condition, incl. fixing unit B38739 B38739 B38739 B38739
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. B33507 B33508 B33508 B33509
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) B33504 B33505 B33505 B33506
Additional water dish B38737 B38000 B38000 B38000
IQ/OQ document with device-specific works test data for one freeselectable CO2 and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICOmed). Price for validation at customer site on demand D38898 D38898 D38898 D38898
IQ/OQ document with device-specific works test data for one free-selectable CO2, humidity and temperature value, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICH C and ICOmed, on models ICOmed a free-selectable humidity value is only possible with option K7). Price for validation at customer site on demand D38897 D38897 D38897 D38897
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189
Hoja perforada de acero inoxidable adicional E35160 E37418 E37418 E35158
Válvula reductora de presión de CO2 conforme a DIN 8546, con monitor de bombas de gas incl. E02087 E02087 E02087 E02087
Válvula reductora de presión de N2 conforme a DIN EN ISO 2503, con monitor de bombas de gas incluido (requiere la opción T6) E06162 E06162 E06162 E06162
Sistema de abastecimiento de agua centralizado con cartuchos de filtros para conectarlo al sistema de abastecimiento de agua doméstico, sólo en combinación con el módulo de humedad. Información sobre el producto a petición ZWVR6 ZWVR6 ZWVR6 ZWVR6
Sistema de abastecimiento de agua centralizado sin cartuchos de filtros para conectarlo al sistema de abastecimiento de agua doméstico (solo usar con agua desmineralizada/completamente desionizada según VDE 0510/DIN EN 50272), solo en combinación con el módulo de humedad. Información sobre el producto a petición ZWVR7 ZWVR7 ZWVR7 ZWVR7
Agitador de mesa Celltron (no admite descuentos): Accesorio si se solicita E06724 E06724 E06724
Prolongación de 1 año para la garantía GA3Q5 GA3Q5 GA3Q5 GA3Q5
Adaptador Ethernet-USB E06192 E06192 E06192 E06192
Dispositivo USB de ID de usuario (licencia de autorización de usuario): La licencia de autorización de usuario específica por equipo (programa de ID de usuario) en el dispositivo de memoria evita la manipulación no deseada del equipo por parte de terceros sin autorización. Indique el número de equipo al realizar un nuevo pedido (sólo para equipos con TwinDISPLAY). B33170 B33170 B33170 B33170
Dispositivo USB con el software de documentación AtmoCONTROL e instrucciones de manejo para productos con SingleDISPLAY (en equipos con TwinDISPLAY incluido en el envío estándar). Indique el número de equipo al realizar un nuevo pedido. B33172 B33172 B33172 B33172
Juego de pies niveladores (4 unidades). De serie con los modelos ICOmed B29768 B29768 B29768 B29768
Juego de apilamiento (4 unidades) para apilar equipos del mismo tamaño (no es apto para los modelos 160, 260, 450, 750 y 1060) Juego de apilamiento (4 unidades) para apilar equipos del mismo tamaño (no es apto para los modelos 160, 260, 450, 750 y 1060) B29744 B29744
Software conforme con la FDA "AtmoCONTROL Edición FDA". Cumple los requisitos necesarios para el uso de registros de datos guardados en formato electrónico y firmas electrónicas según el Título 21 del Código de Reglamentos Federales (CFR, por sus siglas en inglés), sección 11, de la FDA (US Food and Drug Administration). Licencia básica para el control de un equipo (sólo para equipos con TwinDISPLAY). Documento para realizar las pruebas IQ/OQ disponible en alemán y inglés (sin recargo). FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integración de equipos adicionales (hasta un máx. de 15 unidades) en una licencia FDA ya adquirida (sólo para equipos con TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2
Documento para realizar las pruebas IQ con datos de trabajo según el equipo, lista de comprobación para la realización de pruebas OQ/PQ como orientación para las tareas de validación por parte del cliente D00124 D00124 D00124 D00124