Options / Accessories

para Estufa de vacío VO101

La regulación digital de presión proporciona un secado al vacío rapidísimo y suave y la bomba de vacío de velocidad variable ahorra alrededor del 70 % de energía.

Opciones

Opciones N.º de pedido
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) T5
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160 or +180 °C (Please, indicate upon ordering) A8
MobileALERT for 2 alarm notifications; temperature and vacuum alarm (only with option T5) C4
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6
Freely positioned control sensor, MIN and MAX alarm adjustable at ControlCOCKPIT, alarm values captured in internal data logger H9
4 – 20 mA current loop interface (only with option T5) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring - price per sensor V6
4 – 20 mA current loop interface (only with option T5) Vacuum actual value (0 bis 1200 mbar = 4 - 20) W2
4 – 20 mA current loop interface (only with option T5) Temperature actual value (0 to 210 °C = 4 - 20 m) V3
Contacto sin potencial (24 V/2 A) con borne incorporado conforme a NAMUR NE 28 para el envío de señales en función de los segmentos del programa para funciones de periféricos que se pueden activar de forma opcional (p. ej., activación de señales ópticas y acústicas, motores de aspiración, ventiladores, agitadores, etc.), solo para equipos con TwinDISPLAY, máx. 2 unidades con equipos de corriente monofásica. Máx. 4 unidades para equipos con corriente trifásica Equipos, dos contactos Contacto sin potencial (24 V/2 A) con borne incorporado conforme a NAMUR NE 28 para el envío de señales en función de los segmentos del programa para funciones de periféricos que se pueden activar de forma opcional (p. ej., activación de señales ópticas y acústicas, motores de aspiración, ventiladores, agitadores, etc.), solo para equipos con TwinDISPLAY, máx. 2 unidades con equipos de corriente monofásica. Máx. 4 unidades para equipos con corriente trifásica Equipos, dos contactos H7
MobileALERT: notificaciones de alarma a través de un mensaje de texto (SMS) de todo tipo de aviso de alarma o error del equipo. Condición: opción H6 de «contacto sin potencial para avisos de error» C3

Accesorios

Accesorios N.º de pedido
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP101
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM101
Works calibration certificate for 3 temperatures: +50 °C, +100 °C, +160 °C at 20 mbar pressure. Price per thermoshelf D00115
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02037
Signal cable (3 m) for control of roation speed and optimising pump performance by demand-controlled activation of purge of Memmert pump (not required with pump module) B39410
Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressures: approx. 50 Nl./min = 3,0 m/h3 and autom. purge control. Order No. B39410 and B04026 necessary. 230 V, 50 Hz. Max. guarantee period 2 years E07509
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number B33170
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
Integration of additional units (up to max. 15 units) into an alre ady existent FDA-software licence FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
Guarantee extension by 1 year GA2Q5
Termobandejas adicionales de aluminio anodizado, (W. St. N.º 3.3547; ASTM B209) con sistema de calefacción de gran superficie integrado, incl. sistema de sondas incorporado (Pt100, sistema de medición de 4 hilos), protección MLOP contra temperatura excesiva por cada bandeja (Multi-Level-Overtemperature-Protection) y certificado de calibración B00744
Termobandejas adicionales de acero inoxidable (W. St. N.º 1.4404; ASTM 316 L) para materiales especialmente corrosivos, con sistema de calefacción de gran superficie integrada, incl. sistema de sensores incorporado (Pt100, sistema de medición de 4 hilos), protección contra temperatura excesiva indiv. por bandeja (protección MLOP multinivel) y certificado de calibración Termobandejas adicionales de acero inoxidable (W. St. N.º 1.4404; ASTM 316 L) para materiales especialmente corrosivos, con sistema de calefacción de gran superficie integrada, incl. sistema de sensores incorporado (Pt100, sistema de medición de 4 hilos), protección contra temperatura excesiva indiv. por bandeja (protección MLOP multinivel) y certificado de calibración B00735
Tubo flexible de conexión de vacío (3 m) para la estufa con la bomba de Memmert, incl. acc. de conexión optimizados (en parte de acero inoxidable). No es necesario para el pedido, o en caso de formar parte ya del equipamiento del cliente, del módulo de bombeo con bomba. Tubo flexible de conexión de vacío (3 m) para la estufa con la bomba de Memmert, incl. acc. de conexión optimizados (en parte de acero inoxidable). No es necesario para el pedido, o en caso de formar parte ya del equipamiento del cliente, del módulo de bombeo con bomba. B04026
Adaptador Ethernet-USB E06192