Options / Accessories

pour Étuve à vide VO101

La régulation numérique de la pression garantit un séchage sous vide ultra rapide et tout en douceur, la pompe à vide à débit variable permet d’économiser près de 70 % d’énergie.

Options

Options Commande N°
Certificat de calibrage d’usine pour une valeur de témperature et vide (par thermo-plateau) à sélectionner librement D00116
Premium module: comprises the inert gas inlet (only size 49 and 101), extra connectors for thermoshelves, 1 (size 29), 2 (sizes 49/101), an additional thermoshelf (sizes 49/101) T5
Works calibration certificate for 3 temperatures: +50 °C, +100 °C, +160 °C at 20 mbar pressure. Price per thermoshelf D00115
Temperature restriction; Temperatures: +60, +70, +80, +95, +100, +120, +160 or +180 °C (Please, indicate upon ordering) A8
MobileALERT for 2 alarm notifications; temperature and vacuum alarm (only with option T5) C4
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6
Freely positioned control sensor, MIN and MAX alarm adjustable at ControlCOCKPIT, alarm values captured in internal data logger H9
4 – 20 mA current loop interface (only with option T5) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring - price per sensor V6
4 – 20 mA current loop interface (only with option T5) Vacuum actual value (0 bis 1200 mbar = 4 - 20) W2
4 – 20 mA current loop interface (only with option T5) Temperature actual value (0 to 210 °C = 4 - 20 m) V3
Contact sans potentiel (24 V/2 A) avec douille de montage conforme à la norme NAMUR NE 28 pour émission de signaux pilotés par programmation à segments avec libre choix de fonctions externes à activer (activation de signaux sonores et visuels, de moteurs d'extracteurs, de ventilateurs, d'agitateurs, etc.), uniquement pour les appareils TwinDISPLAY, 2 unités maximum pour les appareils 1 ph., 4 unités au maximum avec appareils 3 ph., deux contacts Contact sans potentiel (24 V/2 A) avec douille de montage conforme à la norme NAMUR NE 28 pour émission de signaux pilotés par programmation à segments avec libre choix de fonctions externes à activer (activation de signaux sonores et visuels, de moteurs d'extracteurs, de ventilateurs, d'agitateurs, etc.), uniquement pour les appareils TwinDISPLAY, 2 unités maximum pour les appareils 1 ph., 4 unités au maximum avec appareils 3 ph., deux contacts H7
MobileALERT, envoi d'un SMS en cas de dysfonctionnement ou de déclenchement de l'alarme de l'appareil. Option H6 « Contact sans potentiel pour message d'erreur » nécessaire C3

Accessoires

Accessoires Commande N°
Document IQ/OQ avec données d’usine spécifiques à l’appareil pour une valeur de température et vacuum à sélectionner librement y compris mesure d’homogénéité des températures relative à Memmert sur 5 points de lecture selon DIN 12880:2007-05, liste de contrôle. PQ destinée à assister la validation effectuée par le client; idem pour thermo-plateaux supplémentaires, prix sur demande. D00117
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP101
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM101
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02037
Signal cable (3 m) for control of roation speed and optimising pump performance by demand-controlled activation of purge of Memmert pump (not required with pump module) B39410
Vacuum pump with chemically resistant 4x diaphragm, pump capacity at atm. pressures: approx. 50 Nl./min = 3,0 m/h3 and autom. purge control. Order No. B39410 and B04026 necessary. 230 V, 50 Hz. Max. guarantee period 2 years E07509
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number B33170
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
Inclusion FDA d‘un appareil supplémentaire (max. 15) dans une licence FDA préexistante (compatible avec appareils TwinDISPLAY uniquement) FDAQ2
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
Guarantee extension by 1 year GA2Q5
Thermo-plateaux supplémentaires en aluminium éloxydé, numéro de matériau 3.3547 (ASTM B209) avec chauffage intégré pour grande surface et sondes directes (Pt100, 4 conducteurs), dispositif individuel de surveillance de la surtempérature de la tôle MLOP (Multi-Level-Overtemperature-Control) et certificat de calibrage B00744
Thermo-plateaux supplémentaires en acier inoxydable, numéro de matériau 1.4404 (ASTM 316 L) pour matériaux particulièrement corrosifs, avec chauffage pour grande surface intégré et sondes directes (Pt100, 4 conducteurs), dispositif individuel de surveillance de la surtempérature de la tôle MLOP (Multi-Level-Overtemperature-Control) et certificat de calibrage Thermo-plateaux supplémentaires en acier inoxydable, numéro de matériau 1.4404 (ASTM 316 L) pour matériaux particulièrement corrosifs, avec chauffage pour grande surface intégré et sondes directes (Pt100, 4 conducteurs), dispositif individuel de surveillance de la surtempérature de la tôle MLOP (Multi-Level-Overtemperature-Control) et certificat de calibrage B00735
Tuyau-raccord à vide (3 m) pour relier l'étuve à la pompe Memmert, avec connecteurs optimisés (en partie en acier inoxydable). Pas nécessaire en cas de commande du module de pompe avec la pompe ou si les éléments sont déjà présents. Tuyau-raccord à vide (3 m) pour relier l'étuve à la pompe Memmert, avec connecteurs optimisés (en partie en acier inoxydable). Pas nécessaire en cas de commande du module de pompe avec la pompe ou si les éléments sont déjà présents. B04026
Adaptateur USB-Ethernet E06192