Archive

Options / Accessories / Services

for Constant climate chamber

Our constant climate chamber is tailored to environmental simulation, material testing and stability testing in accordance with the ICH guidelines.

Options

Model sizes 110 260 410 750 1060 1400 2200
Voltage 115 V, 50/60 Hz (no extra cost) X2 X2 X2 X2 X2
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (standard with 1060) K1
Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior,10 for model 110, 14 for model 260/410/750,programme controlled dimming from 0 to 100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T7 T7 T7 T7
Light module cold white 6,500K + warm white 2,700K: LED light strips - 10 stripes for model 110, 14 for model 260/410/750 (6 resp. 8 alternating coldwhite light strips and 4 resp. 6 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T8 T8 T8 T8
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/400/750, programme-controlled dimming rom 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7, D8) T9 T9 T9 T9
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3 R3 R3 R3 R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230V/2, 2A/500W, can be switched on/off via tumbler switch in control panel, moisture tight IP68 R4 R4 R4 R4 R4
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0 F0 F0 F0 F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1 F1 F1 F1 F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2 F2 F2 F2 F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3 F3 F3 F3 F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4 F4 F4 F4 F4 F4 F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5 F5 F5 F5 F5 F5 F5
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location) – rear F6 F6 F6 F6 F6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please, state location; not in combination with T7, T8, T9) F7 F7 F7 F7 F7
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA), temperature controller, actual value V3 V3 V3 V3 V3 V3 V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6 V6 V6 V6 V6 V6 V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) V7 V7 V7 V7 V7 V7 V7
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9 C9 C9 C9 C9 C9 C9
Door with lock and key (safety lock) Door with lock and key (safety lock) B6 B6 B6 B6 B6
Door with lock and key (safety lock), two locks (one each door) B62
Door with lock and key (safety lock), three locks (one each door) B63
Door hinged on the left B8 B8 B8
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6 H6 H6 H6 H6 H6
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4 D4 D4 D4 D4
Process-dependent programmable door lock, two interlocking systems (one each other) D42
Process-dependent programmable door lock, three interlocking systems (one each other) D43
Door-open-recognition (only for units with TwinDISPLAY) V5 V5 V5 V5 V5
Door-open-recognition, two (one each door) V52
Door-open-recognition, three (one each door) V53
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3 C3 C3 C3 C3 C3 C3
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9 R9

Accessories

Model sizes 110 260 410 750 1060 1400 2200
Stainless steel grids, electropolished Stainless steel grids, electropolished E20165 E28891 E28891 E20182 B41251 B38955 B38955
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) Please consider max. loading of chamber E29767 E29766 E29766 B32190 B32550
Perforated stainless steel shelves B00325 B29725 B29725 B00328
Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) Reinforced perforated stainless steel shelf, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1) B32191 B32549
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02073 E29726 E29726 E02075 B32599
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763
Max. loading per slide-in drip tray (kg) 3 4 4 8 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04359 B29722 B29722 B04362 B29769
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055
Max. loading per bottom drip tray (kg) 3 4 4 8 8
Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 410, 750, 1060, 1400 and 2200. E32172 E32172
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6 ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7 ZWVR7
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL). When reordering please specify serial number B33172 B33172 B33172 B33172
Set of height adjustable feet (4 pcs) B29768 B29768
Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of appliances of same size B29744
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29734 B29738 B42116 B29742 B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29735 B29739 B42117 B29743 B29743
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29749 B29751
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29750
Subframe, adjustable in height, height 130 mm B33661 B33664
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPPeco, ICHLeco/ ICHL, IPPecoplus) B04713 B04713 B04713 B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPPeco, ICHeco/ICH, ICHLeco/ICHL, IPPecoplus and ICOmed) B04714 B04714 B04714 B04714 B04714 B04714 B04714

Services

Model sizes 110 260 410 750 1060 1400 2200
Guarantee extension by 1 year GA2Q5 GA3Q5 GA3Q5 GA3Q5 GA4Q5 GA4Q5 GA4Q5
Calibration at Memmert factory for a freely selectable temperature and humidity value D00105 D00105 D00105 D00105 D00105 D00105 D00105
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30) and 27 temperature measuring points (sizes 55 - 1060) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127 D00127 D00127 D00127 D00127 D00127 D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136 D00136 D00136 D00136 D00136 D00136 D00136
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137 D00137 D00137 D00137 D00137 D00137 D00137