Waterbath WNB 45

The combination of corrosion-resistant stainless steel, precise electronics and multiple temperature protection guarantees the highest level of safety in the laboratory.

WNB 45

Waterbath WNB 45

Standard delivery Waterbath

On this page, you can find all the essential technical data on the Memmert water bath. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at sales@memmert.com.

Temperature

Setting temperature range +10 to +95 °C and boiling stage
Working temperature range in °C min. 5 above ambient up to +95 °C with additional boiling mode

Control of standard components

Temperature sensor 1 Pt100 sensor class A in 4-wire-circuit
Timer integrated digital timer from 1 min. to 99,59 hours for: ON continuous operation WAIT (delayed on for continuous and limited timed operation) HOLD

Safety

Temperature control mechanical temperature limiter TB protection class 1 switching the heating off at approx. 30°C above max. temperature of the bath
Temperature control in case of overtemperature due to failure, the heating is switched off at approx. 10°C above the set temperature (fixed value)
Autodiagnostic system microprocessor PID-temperature controller with integrated autodiagnostic system with fault indicator

Heating concept

Heating Baths corrosion-proof large-area heating on three sides

Standard equipment

Controller digital display (LED) of set and actual temperature (0,1°C resolution) and of (remaining) programme time

Stainless steel interior

Dimensions W x H x D in mm w(A) x h(C) x d(B): 590 x 220 x 350 mm
Interior easy-to-clean interior, made of stainless steel, reinforced by deep drawn ribbing, material no. 1.4301 (ASTM 304), laser-welded
Volume 45 l
Liquid level min. (H) 177 mm
Liquid level max. (I) 200 mm

Textured stainless steel casing

Dimensions w(D) x h(G) x d(E): 818 x 401 x 516 mm

Electrical data

Voltage 230 V, 50/60 Hz
Electrical load approx. 2800 W (during heating)

Ambient conditions

Installation The vent openings in the left and back side must remain unobstructed. Minimum wall spacing on all sides is 80 mm. The minimum spacing from the top of the bath to the next ceiling is 750 mm.
Ambient temperature +5 °C to +40 °C
Humidity rh max. 80 %, non-condensing
Overvoltage category II
Pollution degree 2

Packing/shipping data

Transport information The appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton w x h x d: 910 x 610 x 460 mm
Net weight approx. 26 kg
Gross weight carton approx. 33 kg

Standard units are safety-approved and bear the test marks

CE
EAC Eurasian Conformity
VDE-EMC electromagnetic compatibility

More product series of Archive

Constant climate chamber

Constant climate chamber

Our constant climate chamber is tailored to environmental simulation, material testing and stability testing in accordance with the ICH guidelines.

Peltier-cooled incubator

Peltier-cooled incubator

Microbiology, zoology, food, cosmetics or pharma industry: the energy-saving cooled incubator with Peltier elements heats up and cools down seamlessly in one system.

More product categories

Heating / drying ovens

Incubators

Climate chambers

Water and oilbaths