Environmental test chambers CTC / TTC

The environment test duo for temperature test and climate test simulates the perfect atmosphere according to standards and reduces the time needed for certain processes through rapid temperature changes.

Environmental test chambers

Rapid and energy-saving temperature changes in the environmental chamber

Rapid, precise and energy-saving temperature changes in the range from -42 ºC to +190 ºC, along with fast humidity recovery times, make the TTC temperature test chamber and the CTC climatic test chamber with humidity unit a perfect duo for controlled material testing, function tests, ageing tests or climate tests on composites, concrete, plastics or electronic components in material technology, the automotive and aerospace industries, and electronics.
  • 1 model size (256 litres volume)
  • state-of-the-art control technology
  • electronically controlled active humidification and dehumidification from 10% to 98% rh
  • specifically suited for tests in accordance with DIN EN 60068-2-1, 2-2, 2-3
  • high-tech insulation system for permanent insulation capacity and energy efficiency
  • average temperature change speed in heating operation: 10 K/min (-40°C to +180°C)
  • average temperature change speed in cooling operation from +190°C to 0°C: 5 K/min
  • average temperature change speed in cooling operation according to IEC 60068-3-5 (from +180°C to -40°C): 3 K/min
  • chlorine-free, ozone-neutral refrigerant R 404 A

Perfect environmental simulation for climate test and temperature test

The climatic test chamber CTC and temperature test chamber TTC are, with a rated power of 7000 Watts, extremely powerful due to the optimally coordinated heating and cooling technology. Largest possible energy efficiency and reduction in noise had been two criteria for the Memmert engineers to fulfill. With a chamber volume of 256 litres, they provide plenty of space to offer, yet have a low floor space requirement because of their narrow and compact construction. In addition, the appliances can be conveniently moved on castors through any standard laboratory door.

A Memmert environmental chamber CTC/TTC offers unique advantages

  • heating concept specifically adapted for a precise and homogenous temperature control
  • alarm functions, three-fold overtemperature protection and simultaneous display of all parameters provide safety for samples
  • a wide range of options for programming and documentation using interfaces, Celsius software, integrated log memory and chip cards (features dependent on the controller class)
CE

Sectors

Memmert knows exactly, what users from the industry need. Read here, which technological details make a Memmert heating oven, vacuum drying oven or climate chamber uniquely precise, reliable and efficient.

Icon Industry
Industry

Industry

Storing sensitive sensors in a climate chamber with a maximum temperature deviation of 0.2 K? Reducing your process times during vacuum drying to an optimum? Ensuring interruption-free long-term testing? Running experiments with defined air exchange rates? Our industrial applications special introduces suitable appliances as well as case studies.

Applications Detailed information about application to the Memmert products at www.atmosafe.com