Constant climate chamber HPP

Our constant climate chamber is tailored to environmental simulation, material testing and stability testing in accordance with the ICH guidelines.

Constant climate chamber

High-precision stability testing

Are you looking for a stability chamber for environmental simulation, material testing and stability testing which is quiet, space-saving, environmentally friendly and at the same time extremely economical? Then choose the innovative Peltier technology in the HPP constant climate chamber for stable and precise long-term tests. The temperature control from +0 ºC to +70 ºC, as well as the active humidification and dehumidification from 10% to 90% rh, are optimally tuned to the requirements of stability analysis.
  • Temperature range up to +70 °C
  • 6 model sizes (108 to 1360 litres volume)
  • 1 model variant: TwinDISPLAY
  • digitally controlled active humidification and dehumidification up to 90%
  • double doors as standard: prevention of contamination and drops or rises in temperature, and at the same time an optimal view of the sensitive load through wide-area interior glass doors

Energy efficient Peltier technology saves money in the long term

Most stability tests are performed at a temperature close to the ambient temperature. Here, the impressive economy of the heating and cooling concept with Peltier elements can be seen, already proven thousands of times in Memmert appliances. Over the course of a test run lasting several months, energy savings of up to 90 % can be achieved. Because it runs so quietly, the constant climate chamber is ideal not only for environment simulation and long-term material tests, but also for breeding insects, zebra fish and reptiles.

Optional illumination unit for constant climate chamber HPP

If you select the light module option, you can also use this uniquely precise climate chamber for applications such as seed germination, plant cultivation or breeding of zebra fish or insects, especially Drosophila breeding, under a constant climate and under daylight conditions. As an alternative, you can choose cold white light (6,500 Kelvin) or a combination of cold white and warm white light (2,700 Kelvin), dimmable in steps of 1%.

A Memmert constant climate offers unique advantages

  • intuitive and easy-to-use operating menu
  • temperature and humidity ramps programmable via AtmoCONTROL software
  • almost exclusive use of high-quality, corrosion-resistant and easily cleanable stainless steel for the working chamber and housing
  • Peltier heating and cooling concept specifically adapted for a precise and homogenous temperature control
  • a wide range of options for programming and documentation using interfaces, integrated data logger and software AtmoCONTROL

Temperature-humidity working range HPP

Not all climate chambers are the same. The humidity content of the chamber load, the ambient conditions and the respective temperature-humidity working range are decisive factors in the selection of the right appliance. In the adjacent diagram, you can see the possible temperature/humidity combinations for our constant climate chamber HPP.

Within the respective temperature-humidity range, condensation-free permanent operation is possible. To which extent condensation may occur in the threshold range depends on the humidity content of the chamber load and the ambient conditions.

This seems not to be the appropriate device for your temperature-humidity-working range?
See the other Memmert climate chambers.

CE
GOST Система добровольной сертификации

Models

Size

Sectors

Memmert knows exactly, what users from the industry need. Read here, which technological details make a Memmert heating oven, vacuum drying oven or climate chamber uniquely precise, reliable and efficient.

Icon Food
Food

Food

We are dedicated to good taste. In order to ensure the unrivalled reliability and precision of Memmert incubators, ovens and climate chambers we develop and manufacture all vital components ourselves. Read more on Memmert’s solutions for the food and beverage industry on our special application page.

Icon Industry
Industry

Industry

Storing sensitive sensors in a climate chamber with a maximum temperature deviation of 0.2 K? Reducing your process times during vacuum drying to an optimum? Ensuring interruption-free long-term testing? Running experiments with defined air exchange rates? Our industrial applications special introduces suitable appliances as well as case studies.

Icon Pharma
Pharma

Pharma

It is our passion for details that determines the outstanding quality of our temperature control appliances. And due our unconditional focus on the requirements of the customers Memmert appliances have been regulars in the labs of the pharmaceutical industry and life sciences for decades now. You’ll find corresponding case studies and appliances on this page.

Applications Detailed information about application to the Memmert products at www.atmosafe.com