Vacuum oven VO

Digital pressure control ensures rapid and gentle vacuum drying. Its speed-controlled vacuum pump (accessory) saves around 70% energy.

Vacuum oven

Gentle, powerful, energy-saving: Vacuum drying oven VO

Reliable, comfortable and energy-efficient - that’s how vacuum drying works today. Separately adjustable and directly heated thermoshelves ensure precise temperature control and, thanks to the digital pressure control, the chamber load is not only dried at high speed but also extremely gently in our powerful and robust vacuum drying oven. Together with the speed-controlled vacuum pump, the vacuum oven VO forms an unbeatably energy-efficient duo. The pump is perfectly tidied away in the matching base cabinet.
  • Temperature range up to +200 °C
  • Vacuum control range: 5 to 1100 mbar
  • 3 model sizes (29 to 101 litres volume)
  • 1 model variant: TwinDISPLAY
  • Anti-splinter; VDE-tested door construction for all models
  • Pump control: Optimised rinsing of the pump membrane as well as signal output for switching the pump ON/OFF according to requirements.
  • Optional: Pump base cabinet and energy-efficient vacuum pump

Significantly reduced heating-up and processing times in the vacuum drying oven

When vacuum drying large quantities of powder or granulate, the vacuum cycles, which Memmert is the only manufacturer worldwide to offer, come into play perfectly: Two vacuum values can be set, between which the pressure is oscillated under controlled conditions. This way, a large amount of dry air is admitted within a short time, which absorbs humidity and is immediately extracted by the vacuum pump.

Climate-friendly accessories: Vacuum pump saves around 70 % energy

The spectrum for vacuum drying in a Memmert vacuum oven VO ranges from foodstuffs to cosmetics, granulate, watches, books, printed circuit boards, to electronic components or injection moulds.
Due to the low final vacuum of the speed-controlled, chemical-resistant vacuum pump of up to 2 mbar - the aforementioned is possible.
The demand-oriented pump control ensures a significantly longer service life for the membranes. The energy-saving potential is particularly impressive compared to an uncontrolled vacuum pump. With representative measurements in ramp operation, energy consumption was around 70 % lower, and even better values were achieved with a constant vacuum value.
The speed-controlled Memmert vacuum pump is automatically detected by every vacuum drying oven VO. In the event that another vacuum pump or a central vacuum supply is connected, the vacuum is controlled via solenoid valves.

Uniquely precise: The Memmert VO direct heating system

Multi-Level-Heating & Sensing: intelligent direct heating via individually placeable thermoshelves with separate sensors guarantees short heating and process times in the Memmert vacuum drying oven. The control circuits react precisely to different loads or humidity and maintain a constant set temperature during vacuum drying. Thanks to the direct contact between the heating and the load, practically no heat loss occurs. Each thermoshelf can be individually calibrated.

A Memmert vacuum drying oven offers unique advantages

  • user-friendly, intuitive operating concept
  • Nearly exclusive use of high-quality, rust-resistant and easy to clean stainless steel for interior and exterior housing
  • precise and homogenous temperature control thanks to a product-specific heating concept
  • a wide range of options for programming and documentation using interfaces, integrated data loggers and the AtmoCONTROL software
  • 3 years guarantee worldwide

Would you like to know more about the vacuum oven VO? In our webinar area you will find the recording about the product presentation.

Standard units are safety-approved and bear the test marks

CE
VDEGS
cMET
EAC Eurasian Conformity

Sectors

Memmert knows exactly, what users from the industry need. Read here, which technological details make a Memmert heating oven, vacuum drying oven or climate chamber uniquely precise, reliable and efficient.

Icon Pharma
Pharma

Pharma

Due to our unconditional focus on the requirements of the customers, Memmert appliances have been regulars in the labs of the pharmaceutical industry and life sciences for decades now. Please find corresponding case studies and appliances on this page.

Icon Food
Food

Food

We are dedicated to good taste. In order to ensure the unrivalled reliability and precision of Memmert incubators, ovens and climate chambers, we develop and manufacture all vital components ourselves. Read more on Memmert’s solutions for the food and beverage industry on our special application page.

Icon Industry
Industry

Industry

Storing sensitive sensors in a climate chamber with a maximum temperature deviation of 0.2 K?
Reducing your process times during vacuum drying to an optimum thanks to program-controlled cycles for ventilation and temperature?
Ensuring interruption-free, long-term testing?
Running experiments with defined air exchange rates?
We've got you covered!

Applications Detailed information about application to the Memmert products at www.atmosafe.net