Waterbath WPE 45

The combination of corrosion-resistant stainless steel, precise electronics and multiple temperature protection guarantees the highest level of safety in the laboratory.

WPE 45

Waterbath WPE 45

Standard delivery Waterbath

On this page, you can find all the essential technical data on the Memmert water bath. Our customer relations team will be pleased to help if you want further information. If you should require a customised special solution, please contact our technical specialists at myAtmoSAFE@memmert.com.

Sketch Waterbath WPE 45


Control of standard components

Vacuum pump can be switched on and off
Vacuum pump is switched off at programme end
Controller Electronic microprocessor temperature controller with auto-diagnostic system
Controller digital display (LED) of all set parameters, such as temperature and alarm values (0,1°C resolution) as well as time values
Timer digital timer from 1 min. up to 999 hours for: ON (continuous operation), DELAYED ON, HOLD or HOLD set-temperature dependent with guaranteed holding time


Temperature range in °C min. 15°C above ambient up to +95°C
resolution of display and setting accuracy +0,1°C below 99,9°C, 1°C above 100°C

Control technology

Calibration on controller


Temperature control 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
Temperature control mechanical temperature limiter TB protection class 1 switching the heating off at approx. 30°C above max. temperature of the bath
Temperature control independently working, electronic overtemperature controller TWW protection class 3.1 or overtemperature limiter TWB protection class 2, adjustable in set-up menu by customer
Temperature control in case of overtemperature due to failure, the heating is switched off at approx. 10°C above the set temperature (fixed value)
Autodiagnostic system fuzzy-supported PID microprocessor controller with integrated autodiagnostic system with fault indication
Alarm visual and acoustic alarm at programme end and as input acknowledgement as well as in case of low liquid level, heating is switched off automatically

Heating concept

corrosion-proof large-area heating on three sides

Standard equipment

Interior easy-to-clean interior, made of stainless steel, reinforced by deep drawn ribbing, material no. 1.4301 (ASTM 304), laser-welded
Interior material 1.4301 (ASTM 304), corrosion resistant

Stainless steel interior

Dimensions W x H x D in mm w(A) x h(B) x d(C): 590 x 350 x 220 mm
Volume 45 l

Textured stainless steel casing

w(D) x h(E) x d(F): 818 x 516 x 296 mm

Electrical data

Voltage 230 V, 50/60 Hz
Electrical load approx. 2800 W (during heating)

Packing/shipping data

the appliances must be transported upright
Customs tariff number 8419 8998
Country of origin Federal Republic of Germany
WEEE-Reg.-No. DE 66812464
Dimensions approx incl. carton B x H x T: 910 x 610 x 460 mm
Net weight approx. 26 kg
Gross weight carton approx. 33 kg