|
Voltage 115 V, 50/60 Hz |
X2 |
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (ICHeco/ICH and ICH C only) |
K1 |
|
Illumination unit (has to be ordered together with the chamber) consisting of 4 fluorescent lights with cold white light and 2 UV lamps according ICH Q1B, option 2, separately switchable via controller (only ICHeco L/ICH L) second box |
T72 |
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light according to ICH guideline Q1B, option 2 (only ICHeco L/ICH L); one box |
T81 |
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light according to ICH guideline Q1B, option 2 (only ICHeco L/ICH L); second box (cannot be switched on separately) |
T82 |
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, with UV-A radiation according to ICH guideline Q1B, option 2 (only ICHeco L/ICH L); one box, no extra cost |
T01 |
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, with UV-A radiation according to ICH guideline Q1B, option 2 (only ICHeco L/ICH L); second box, cannot be switched on seperately |
T02 |
|
Interior socket, ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (not for ICH110eco L/ICH110L) |
R3 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre |
F0 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top |
F1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top |
F3 |
|
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) Not for models ICHeco L/ICH L |
F7 |
|
4 to 20 mA current loop interface, temperature controller actual value (-20 to +70 °C = 4 - 20 mA) |
V3 |
|
4 to 20 mA current loop interface, temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3) - price per sensor (-20 to +70 °C = 4 - 20 mA) |
V6 |
|
4 to 20 mA current loop interface, humidity controller, actual value (0 to 100 % rh = 4 - 20 mA) |
V7 |
|
Fan speed monitoring with switching off the heating and with alarm in case of failure |
V4 |
|
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air – for models ICH and ICH L). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. |
C9 |
|
Door with lock and key (safety lock) |
B6 |
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
|
Door-open-recognition, shuts down humidity, light and CO2 (standard with ICH C and ICHeco L/ICH L) |
V5 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) |
C3 |