Options / Accessories / Services

for Constant climate chamber HPP110eco

Maximum energy efficiency in continuous operation - tailor-made for stability studies according to ICH guidelines, stability tests for cosmetics and foods as well as environmental testing and material testing

Options

Options Order No.
Temperature restriction; Temperature: +60 °C A8
Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior, 10 for model 110, 14 for model 260/410/750, programme controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6 T7
Light module cold white 6,500 K + warm white 2,700 K: LED light strips - 10 stripes for model 110, 14 for model 260/410/750 - (5 resp. 7 alternating cold white light strips and 5 resp. 7 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6 T8
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/410/750, pro­gramme-controlled dimming from 0 to 100 % (in 1 % steps), ramp programming in combination with temperature and humidity; not in combination with F6 T9
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location; not in combination with T7, T8, T9) – rear Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location; not in combination with T7, T8, T9) – rear F6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please state location) F7
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, standard position rear D8
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature controller, actual value V3
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Door with lock and key (safety lock) Door with lock and key (safety lock) B6
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3
MobileALERT for 2 alarm notifications; notification by SMS. temperature and humidity alarm C4
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9

Accessories

Accessories Order No.
Stainless steel grids, electropolished Stainless steel grids, electropolished E20165
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) Please consider max. loading of chamber E29767
Perforated stainless steel shelves B00325
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02073
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04359
Holder for water tank (sizes 110 - 750: 2.5 litres, sizes 1060/1400/2200: 10 litres) for mounting on the rear of the appliance. Standard equipment for sizes 410, 750, 1060, 1400 and 2200. B49092
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7
Max. loading per slide-in drip tray (kg) 3
Max. loading per bottom drip tray (kg) 3
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
Set of height adjustable feet (4 pcs) B29768
Stacking set (4 pcs) for stacking of appliances of same size Stacking set (4 pcs) for stacking of appliances of same size B29744
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29734
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29735
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29749
Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) Subframe, on castors (size 30 to 75: height 660 mm, size 110 to 160: height 560 mm) B29750
Subframe, adjustable in height, height 130 mm B33661
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPPeco, ICHLeco/ ICHL, IPPecoplus) B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPPeco, ICHeco/ICH, ICHLeco/ICHL, IPPecoplus and ICOmed) B04714

Services

Services Order No.
Guarantee extension by 1 year GA2Q5
Calibration at Memmert factory for a freely selectable temperature and humidity value D00105
Calibration at Memmert factory for a freely selectable temperature value D00109
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697
DAkkS calibration at Memmert factory for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) E48847
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature and humidity value according to method C (DKD-R 5-7) E48848
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200) and 26 temperature measuring points (size 1400) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
IQ/OQ document with device-specific works test data, including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space at Memmert factory for a freely selectable temperature and humidity value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00136
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature and humidity value D49122
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature, humidity and light intensity value D49125
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Calibration on site for a freely selectable temperature and humidity value (travel costs are not included yet) S00207
Extension of calibration on site by an additional freely selectable temperature value S00215
Extension of calibration on site by an additional freely selectable temperature and humidity value S00216
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360
DAkkS calibration on site for a freely selectable temperature and humidity value according to method C (DKD-R 5-7) (travel costs are not included yet) S00365
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
IQ/OQ qualification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
OQ requalification on site including temperature distribution survey with 27 temperature measuring points (sizes 110 - 1060, 2200), 26 temperature measuring points (size 1400) and 1 humidity measuring point in centre of usable space for a freely selectable temperature and humidity value according to DIN12880:2007-05 (travel costs are not included yet) DLQ101R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature and humidity value DLQ101A
PQ qualification on site (travel costs are not included yet) DLQ200
Maintenance on site HPPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00314
Maintenance contract on site HPPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00314J