|
Voltage 115 V, 50/60 Hz (no extra cost) |
X2 |
X2 |
X2 |
X2 |
X2 |
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. |
B0 |
B0 |
B0 |
B0 |
B0 |
|
Gas inlet/outlet through 2 tubes with ball valves - technical clarification required for combination with other options |
K3 |
K3 |
K3 |
K3 |
K3 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre/centre - technical clarification required |
F0 |
F0 |
F0 |
F0 |
F0 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position left centre top - technical clarification required |
F1 |
F1 |
F1 |
F1 |
F1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre/centre - technical clarification required |
F2 |
F2 |
F2 |
F2 |
F2 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, standard position right centre top - technical clarification required |
F3 |
F3 |
F3 |
F3 |
F3 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - left - technical clarification required |
F4 |
F4 |
F4 |
F4 |
F4 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - right - technical clarification required |
F5 |
F5 |
F5 |
F5 |
F5 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, gas tight, can be closed by flap and silicone stopper, in special positions (please, state location) - rear - technical clarification required |
F6 |
F6 |
F6 |
F6 |
F6 |
|
Entry port, 40 mm clear diameter, for introducing connections, gas tight, can be closed by flap and silicone stopper, in special positions at the back (please, state location) - technical clarification required |
F7 |
F7 |
F7 |
F7 |
F7 |
|
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA)
Temperature controller actual value |
V3 |
V3 |
V3 |
V3 |
V3 |
|
4 – 20 mA current loop interface (0 to +90°C corresponds to 4 – 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring
(max. 3 TwinDISPLAY) |
V6 |
V6 |
V6 |
V6 |
V6 |
|
Door with lock and key (safety lock) |
B6 |
B6 |
B6 |
B6 |
B6 |
|
Door hinged on the left |
B8 |
B8 |
B8 |
B8 |
B8 |
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
H6 |
H6 |
H6 |
H6 |
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts |
H72 |
H72 |
H72 |
H72 |
H72 |
|
Process-dependent programmable door lock (only for units with TwinDISPLAY) |
D4 |
D4 |
D4 |
D4 |
D4 |
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5 |
V5 |
V5 |
V5 |
V5 |
|
Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software |
H8 |
H8 |
H8 |
H8 |
H8 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) |
C3 |
C3 |
C3 |
C3 |
C3 |
|
Castor frame (2-part), height 140 mm |
R9 |
R9 |
R9 |
R9 |
R9 |