|
Temperature restriction (for models UN/UF/UNplus/UFplus, IN/IF/INplus/IFplus) Temperatures: +60, +70, +80, +95, +100, +120, +160, +180, +200 or +220 °C (Please, indicate upon ordering) |
A8 |
|
Full-sight glass door (4 insulating glass). Temperature-range up to max. 250 °C. |
B0 |
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) - includes replacement of standard grids by reinforced grids (standard with 1060) |
K1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre |
F0 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top |
F1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre |
F2 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top |
F3 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left |
F4 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right |
F5 |
|
Locking mechanism to prevent simultaneous opening of doors for contamination protection in case of wall installation (requires option V5) |
D5 |
|
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA)
Temperature controller actual value |
V3 |
|
4 – 20 mA current loop interface (0 to +260 °C ≙ 4 - 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber fo external temperature monitoring (max. 1 SingledDISPLAY, max. 3 TwinDISPLAY) - price per sensor |
V6 |
|
Fan speed monitoring with switching off the heating and with alarm in case of failure |
V4 |
|
Door with lock and key (safety lock) |
B6 |
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts |
H72 |
|
Process-dependent electromagnetic door lock (both sides) |
D4 |
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5 |
|
Flexible Pt100 temperature sensor, positioned fl exibly in chamber or load, for local temperature measurement (up to 1 additional sensor is possible). The measured temperature will be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software |
H8 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) |
C3 |