Options / Accessories / Services

for Peltier-cooled incubator IPP2200eco

Sets eco standards for cultivation below room temperature: unmatched energy efficiency, best values for heat-up, cool-down and recovery times.

Options

Options Order No.
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, standard position rear D8
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 – 20 mA) Temperature controller actual value V3
Door with lock and key (safety lock), three locks (one each door) B63
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Process-dependent programmable door lock, three interlocking systems (one each other) D43
Door-open-recognition, three (one each door) V53
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3

Accessories

Accessories Order No.
Stainless steel grids, electropolished Stainless steel grids, electropolished B38955
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL). When reordering please specify serial number B33172
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714

Services

Services Order No.
Guarantee extension by 1 year GA4Q5
Calibration at Memmert factory for a freely selectable temperature value D00109
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
Extension of DAkkS calibration at Memmert factory by an additional freely selectable temperature value according to method C (DKD-R 5-7) E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data, including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 26 temperature measuring points (size 1400) at Memmert factory for a freely selectable temperature value according to DIN12880:2007-05 (PQ check list as support for validation by customer) D00127
Extension of IQ/OQ document at Memmert factory by an additional freely selectable temperature value D49121
Short training on the handling and use of the device on site (outside Germany price on request) S49128
Calibration on site for a freely selectable temperature value (travel costs are not included yet) S00205
Extension of calibration on site by an additional freely selectable temperature value S00215
DAkkS calibration on site for a freely selectable temperature value according to method C (DKD-R 5-7) (travel costs are not included yet) S00360
IQ/OQ qualification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 28 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100
OQ requalification on site including temperature distribution survey with 9 temperature measuring points (size 30), 27 temperature measuring points (sizes 55 - 1060, 2200) and 26 temperature measuring points (size 1400) for a freely selectable temperature value according to DIN12880:2007-05 (travel costs are not included yet) DLQ100R
Extension of IQ/OQ qualification or OQ requalification on site by an additional freely selectable temperature value DLQ100A
PQ qualification on site (travel costs are not included yet) DLQ200
Maintenance on site IPP/ IPPeco according to Memmert maintenance plan (available on request) (travel costs are not included yet) S00317
Maintenance contract on site IPP/ IPPeco according to Memmert maintenance plan (available on request), minimum duration 3 years (travel costs are not included yet) S00317J