Voltage 115 V, 50/60 Hz |
X2 |
|
X2 |
|
X2 |
|
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids (ICH and ICH C only) |
|
|
|
|
K1 |
K1 |
|
Illumination unit consisting of 4 fluorescent lights with cold white light (standard illuminant D65, 6,500 K) and 2 UV lamps in the spectral range of 320 to 400 nm, 8 W/m2, acc. ICH Q1B option 2, light intensity approx. 8,000 Lux, separately switchable via controller (only ICHeco L/ ICH L) second box |
|
|
T72 |
T72 |
T72 |
T72 |
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) one box |
T81 |
T81 |
T81 |
T81 |
T81 |
T81 |
|
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) second box (cannot be switched on separately) |
|
|
T82 |
T82 |
T82 |
T82 |
|
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) one box, no extra cost |
T01 |
T01 |
T01 |
T01 |
T01 |
T01 |
|
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) second box, cannot be switched on seperately |
|
|
T02 |
T02 |
T02 |
T02 |
|
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 |
R3 |
R3 |
R3 |
R3 |
R3 |
R3 |
|
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 |
R4 |
R4 |
R4 |
R4 |
R4 |
R4 |
|
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) |
|
|
F7 |
F7 |
F7 |
F7 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre |
F0 |
F0 |
F0 |
F0 |
F0 |
F0 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top |
F1 |
F1 |
F1 |
F1 |
F1 |
F1 |
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top |
|
|
F3 |
F3 |
F3 |
F3 |
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
Temperature controller, actual value |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
Humidity controller, actual value (0 – 100 % corresponds to rh 4 – 20 mA) |
V7 |
V7 |
V7 |
V7 |
V7 |
V7 |
|
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA)
(Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible)
CO2 controller, actual value (0 – 25 % CO2 corresponds to 4 – 20 mA) |
V9 |
|
V9 |
|
V9 |
|
|
Fan speed monitoring with switching off the heating and with alarm in case of failure |
V4 |
V4 |
V4 |
V4 |
V4 |
V4 |
|
Works calibration certificate for one (freely selectable) temperature and humidity value |
D00105 |
D00105 |
D00105 |
D00105 |
D00105 |
D00105 |
|
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air – for models ICH and ICH L). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. |
C9 |
C9 |
C9 |
C9 |
C9 |
C9 |
|
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 |
B6 |
B6 |
B6 |
B6 |
B6 |
B6 |
|
Door hinged on the left |
B8 |
B8 |
B8 |
B8 |
|
|
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) |
H5 |
H5 |
H5 |
H5 |
H5 |
H5 |
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
|
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts |
H72 |
H72 |
H72 |
H72 |
H72 |
H72 |
|
Process-dependent programmable door lock (only for units with TwinDISPLAY) |
D4 |
D4 |
D4 |
D4 |
D4 |
D4 |
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5 |
V5 |
V5 |
V5 |
V5 |
V5 |
|
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 2 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral data store, and can be documented via the AtmoCONTROL software |
H8 |
H8 |
H8 |
H8 |
H8 |
H8 |
|
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors |
H4 |
H4 |
H4 |
H4 |
H4 |
H4 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |