Options / Accessories

for Climate Chamber ICH750

Unparalleled homogeneity of temperature and humidity! For stability testing according to ICH - WHO - EMA - ASEAN - GMP - GLP – GCCP.

Option

Option Order No.
Voltage 115 V, 50/60 Hz X2
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids (ICH and ICH C only) K1
Illumination unit consisting of 4 fluorescent lights with cold white light (standard illuminant D65, 6,500 K) and 2 UV lamps in the spectral range of 320 to 400 nm, 8 W/m2, acc. ICH Q1B option 2, light intensity approx. 8,000 Lux, separately switchable via controller (only ICHeco L/ ICH L) second box T72
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) one box T81
Alternative light boxes (replace the standard lighting; have to be ordered together with the chamber); number of fluorescent lamps: size 110: 5, sizes 260/750: 6, with cold white light (daylight: light colour 865, 6.500K; daylight complies with standard illuminant D65) (only ICHeco L/ICH L) second box (cannot be switched on separately) T82
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) one box, no extra cost T01
Alternative light boxes (replace the standard lighting, have to be ordered together with the chamber), number of fluorescent UV lamps: size 110: 5, sizes 260/750: 6, in the spectral range of 315 to 400 nm, 22 W/m2, (only ICH L) second box, cannot be switched on seperately T02
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 R4
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) F7
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) Temperature controller, actual value V3
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) Humidity controller, actual value (0 – 100 % corresponds to rh 4 – 20 mA) V7
4 to 20 mA current loop interface (-20 to +70°C corresponds to 4 to 20 mA) (Models ICH C max. 2 interfaces – only combination V3 + V7 or V3 + V9 possible) CO2 controller, actual value (0 – 25 % CO2 corresponds to 4 – 20 mA) V9
Fan speed monitoring with switching off the heating and with alarm in case of failure V4
Works calibration certificate for one (freely selectable) temperature and humidity value D00105
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air – for models ICH and ICH L). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 B6
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3

Accessory

Accessory Order No.
CO2 pressure reducing valve to DIN 8546, incl. gas cylinder monitor (only ICH C) E02087
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E20182
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) B32190
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 B32191
Perforated stainless steel shelves B00328
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02075
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763
Max. loading per slide-in drip tray (kg) 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04362
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055
Max. loading per bottom drip tray (kg) 8
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer (models ICHeco L/ICH L). Price for validation at customer site on demand (GER, AT, CH only) D00137
External measuring instrument with sensors for daylight and UV-light. Product information on demand (models HPP, ICH L, IPPplus) B04713
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714