Options / Accessories

for CO2 Incubator (med)

Protection for in vitro growing cell cultures, tissue cultures and bacteria cultures in a controlled and physiologically ideal environment.

Option

Model sizes 108 153 246
Voltage 115 V, 50/60 Hz (no extra cost) X2 X2 X2
Door-hinges on left side B8 B8 B8
Stacking version for 2 units of equal size (bottom unit modification) G3 G3 G3
Comfort module: two gas connections with quick release connectors, automatic switch-over of gas cylinders T1 T1 T1
Hygiene module: electropolished interior seamlessly welded by laser T2 T2 T2
Communication module: USB interface, "Celsius" standard software for programming and logging, ring log memory, printer interface T3 T3 T3
CO2 module: extended CO2 range from 0 to 20 % T4 T4 T4
Premium module: includes Comfort, Hygiene, Communication and CO2 module T5 T5 T5
Humidity-Modul: active microprocessor control for humidifying and dehumidifying (40-97 % rh), incl. digital indication and auto-diagnostic system ensures even more rapid reaching of set humidity and very short recovery times while avoiding condensate formation, recommended for applications with set O2 values of less than 10 %, humidity supply with distilled water (from an external tank) by a self-priming pump, integral bacteria block by generating hotsteam, dehumidifying via sterile filter, (standard humidity limit control and water dishes are omitted). Can only be ordered together with new incubator K7 K7 K7
O2 module: control of oxygen concentration by N2 inlet, adjustment range 1 % up to 20 % O2, setting accuracy 0,1 %, (Combination of comfort module or Premium module and O2 module not possible), for applications with a set O2-value of less than 10 %, the humidity module is highly recommended. T6 T6 T6
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back either centre right or centre left (please, state location) F7 F7 F7
Potential-free contact (24V/2A) with socket 3 pin,
according to NAMUR NE 28 for external monitoring
(setpoint of temperature and CO2 is reached) Potential-free contact (24V/2A) with socket 3 pin, according to NAMUR NE 28 for external monitoring (setpoint of temperature and CO2 is reached) H5 H5 H5
Works calibration certificate for 5 %, 7 % and 10 % CO2 (measured at +37°C) D00106 D00106 D00106
Start-up of INCO incubators and brief training (D, A, CH only), through MEMMERT service, not subject to discount K9 K9 K9
4-part partitioning of interior with gas baffle (replacement of 3 full-width by 6 half-width shelves) K4
Interface Ethernet instead of USB including software W4 W4 W4
RS232 interface instead of USB W6 W6 W6
Computer interface RS485 (for networking a max. of 16 ovens) instead of RS232 V2 V2 V2
Door with lock (safety lock, not available for VO, VOcool, TTC/CTC) B6 B6 B6
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4 H4 H4
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) H8 H8 H8
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) H5 H5 H5
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6 H6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) H7 H7 H7

Accessory

Model sizes 108 153 246
Additional perforated stainless steel shelf, full width Additional perforated stainless steel shelf, full width B00325 B00321 B03813
Additional stainless steel grid, full width Additional stainless steel grid, full width E20165 E20166 E29766
Additional water dish (half width model 246) Additional water dish (half width model 246) B02787 B02784 B02786
Subframe (622 mm high) Subframe (622 mm high) B02792 B02732 B02793
Subframe (130 mm hight for 2 stacked incubators) B02794 B02740 B02795
HEPA-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit B04459 B04459 B04459
STERICard (additional or as replacement) for automatic chamber sterilisation cycle (not for sterilising load) E04337 E04337 E04337
CO2 pressure reducing valve DIN 8546, incl. Gas cylinder monitor E02087 E02087 E02087
N2 pressure reducing valve to DIN EN ISO 2503, incl. gas cylinder monitor for O2 module E06162 E06162 E06162
CO2 connection set, hose with coupling and clamp B03881 B03881 B03881
Central water supply with filter cartridges for connection to the domestic water supply (only for demineralised water in accordance with VDE 0510/DIN EN 50272), only in combination with option K7. Product information on demand ZWVR6 ZWVR6 ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water in accordance with VDE 0510/DIN EN 50272), only in combination with option K7. Product information on demand ZWVR7 ZWVR7 ZWVR7
Celltron benchtop shaker (not subject to discount) – accessories upon request E06724 E06724 E06724
Additional perforated stainless steel shelve, half width B02742
Guarantee extension by 1 year GA2Q5 GA2Q5 GA2Q5
USB connection cable for computer interface E03643 E03643 E03643
Parallel/USB converter cable with integrated power supply unit to connect HP printers with USB interface to MEMMERT units. Not applicable for UFP800DW E05300 E05300 E05300
Documentation package consisting of parallel USB converter cable including PCL3-compatible HP colour inkjet printer with USB interface (HP OfficeJet 6000 or successor) for direct connection of printer to Memmert unit. Not applicable for UFP800DW B04432 B04432 B04432
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps E05284 E05284 E05284
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) E04004 E04004 E04004
Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number E04159 E04159 E04159
Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Not applicable for UFP800DW E05019 E05019 E05019
Integration of additional units (up to max.16 units) into an already existent FDA-software licence. Not applicable for UFP800DW FDAQ4 FDAQ4 FDAQ4
IQ check list with works test data for chamber as support for validation by customer D00103 D00103 D00103
OQ check list with works test data for one free-selectable temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer D00104 D00104 D00104
OQ check list with works test data for one free-selectable temperature and vacuum value incl. temperature distribution survey for 5 measuring points to DIN 12880:2007-05 as support for validation by customer (VO, VOcool only) valid for one thermoshelf, dito for further thermoshelves VO: EUR 340,– each D00117 D00117 D00117
OQ check list with works test data for one free-selectable humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models HCP and CTC) D00104 D00104 D00104
OQ check list with works test data for one free-selectable CO2, humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models INCOmed) D00104 D00104 D00104
External measuring instrument with sensors for daylight and UV-light, with additional measuring head for temperature and humidity. Product information on demand (models INCOmed and HCP) B04714 B04714 B04714