Additional perforated stainless steel shelf |
E35160 |
E37418 |
E37418 |
E35158 |
|
Additional water dish (not applicable with option K7) |
B38737 |
B38737 |
B38737 |
B38737 |
|
Central water supply with filter cartridges for connection to the domestic water supply, only in combination with option K7. Product information on demand |
ZWVR6 |
ZWVR6 |
ZWVR6 |
ZWVR6 |
|
Central water supply, without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7) only in combination with option K7. Product information on demand |
ZWVR7 |
ZWFR7 |
ZWVR7 |
ZWVR7 |
|
HEPA14-filter for chamber according to EN 1822, packed in sterile condition, incl. fixing unit |
B49800 |
B49800 |
B49800 |
B49800 |
|
3 HEPA14-filters (B49800) for chamber according to EN 1822, packed in sterile condition, incl. fixing unit |
B39698 |
B39698 |
B39698 |
B39698 |
|
Guarantee extension by 1 year |
GA3Q5 |
GA3Q5 |
GA3Q5 |
GA3Q5 |
|
USB-Ethernet adapter |
E06192 |
E06192 |
E06192 |
E06192 |
|
Ethernet connection cable 5 m for computer interface |
E06189 |
E06189 |
E06189 |
E06189 |
|
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) |
B33170 |
B33170 |
B33170 |
B33170 |
|
Stacking set (4 pcs) for stacking of appliances of same size (not for models 160, 260, 450, 750, 1060, ICH110, ICH110L and ICH110C) |
B29744 |
B29744 |
|
|
|
Stacking set (consisting of stacking corners, one connecting plate for the rear, two wall brackets) for stacking of two units of same size (size 240 only in combination with subframe B33509 or B43598) |
|
|
B42114 |
B48129 |
|
Subframe (130 mm high); sizes 150/240: only in combination with the corresponding stacking sets for stacked appliances. |
B33507 |
B33508 |
B33508 |
B33509 |
|
Subframe (622 mm high) adjustable in height (sizes 150/240: should not be used for 2 stacked units) |
B33504 |
B33505 |
B33505 |
B33506 |
|
Subframe, on castors (height 120 mm; stainless steel, material 1.4301) |
|
|
|
B43598 |
|
CO2 pressure reducing valve DIN 8546, incl. Gas cylinder monitor |
E02087 |
E02087 |
E02087 |
E02087 |
|
N2 pressure reducing valve to DIN EN ISO 2503, incl. gas cylinder monitor (requires option T6) |
E06162 |
E06162 |
E06162 |
E06162 |
|
Celltron benchtop shaker (not subject to discount) – accessories upon request |
|
|
|
E06724 |
|
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence |
FDAQ2 |
FDAQ2 |
FDAQ2 |
FDAQ2 |
|
IQ/OQ document with device-specific works test data for one freeselectable
CO2 and temperature value, incl. temperature distribution
survey at Memmert for 27 measuring points to DIN 12880:2007-05,
PQ check list as support for validation by customer (models ICOmed). |
D38898 |
D38898 |
D38898 |
D38898 |
|
IQ/OQ document with device-specific works test data for one
free-selectable CO2, humidity and temperature value, incl.
temperature distribution survey at Memmert for 27 measuring
points to DIN 12880:2007-05, PQ check list as support for
validation by customer (models ICH C and ICOmed, on models ICOmed
a free-selectable humidity value is only possible with option K7). |
D38897 |
D38897 |
D38897 |
D38897 |
|
Software conforming to FDA AtmoCONTROL. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for reading the data logging of one unit (only for units with TwinDISPLAY). Respective IQ/OQ documents available in German and English language (without surcharge) |
FDAQ1 |
FADQ1 |
FDAQ1 |
FDAQ1 |
|
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer |
D00124 |
D00124 |
D00124 |
D00124 |
|
External measuring instrument with additional measuring head for temperature and humidity measurement. Product information on demand |
B04714 |
B04714 |
B04714 |
B04714 |
|
DAkkS calibration for one (freely selectable) temperature and humidity value according to method C (DKD-R 5-7) (requires option K7) |
E48847 |
E48847 |
E48847 |
E48847 |
|
DAkkS calibration for further temperature and humidity values according to method C (DKD-R 5-7) (requires option K7) |
E48848 |
E48848 |
E48848 |
E48848 |
|
On-site IQ/OQ for a freely selectable temperature and CO2 value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (models ICH C) (excluding travel costs, not subject to discount, GER, AT, FR only) |
DLQ102 |
DLQ102 |
DLQ102 |
DLQ102 |
|
Extension of DLQ102 by an additional freely selectable temperature and CO2 value (models ICH C) (not subject to discount) |
DLQ102A |
DLQ102A |
DLQ102A |
DLQ102A |
|
On-site IQ/OQ for a freely selectable temperature, humidity and CO2 value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (models ICH C) (excluding travel costs, not subject to discount, GER, AT, FR only) |
DLQ103 |
DLQ103 |
DLQ103 |
DLQ103 |
|
Extension of DLQ103 by an additional freely selectable temperature, humidity and CO2 value (requires option K7) (not subject to discount) |
DLQ103A |
DLQ103A |
DLQ103A |
DLQ103A |
|
On-site IQ/OQ for a freely selectable temperature, CO2 and O2 value, including temperature distribution survey for 27 measuring points to DIN 12880:2007-05 (requires option T6) (excluding travel costs, not subject to discount, GER, AT, FR only) |
DLQ104 |
DLQ104 |
DLQ104 |
DLQ104 |
|
Extension of DLQ104 by an additional freely selectable temperature, CO2 and O2 value (requires option T6) (not subject to discount) |
DLQ104A |
DLQ104A |
DLQ104A |
DLQ104A |
|
On-site IQ/OQ for a freely selectable temperature, humidity, CO2 and O2 value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (requires option K7 and T6) (excluding travel costs, not subject to discount, GER, AT, FR only) |
DLQ105 |
DLQ105 |
DLQ105 |
DLQ105 |
|
Extension of DLQ105 by an additional freely selectable temperature, humidity, CO2 and O2 value (requires option K7 and T6) (not subject to discount) |
DLQ105A |
DLQ105A |
DLQ105A |
DLQ105A |
|
Individual on-site Performance Qualification (PQ) |
DLQ200 |
DLQ200 |
DLQ200 |
DLQ200 |
|
Maintenance ICO/ ICOmed passive humidity - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) |
S00323 |
S00323 |
S00323 |
S00323 |
|
Maintenance contract ICO/ ICOmed passive humidity - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) |
S00323J |
S00323J |
S00323J |
S00323J |
|
Maintenance ICO/ ICOmed active humidity - carrying out and documentation according to Memmert maintenance plan (requires option K7) (excluding travel costs, not subject to discount, GER, AT, FR only) |
S00312 |
S00312 |
S00312 |
S00312 |
|
Maintenance contract ICO/ ICOmed active humidity - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (requires option K7) (excluding travel costs, not subject to discount, GER, AT, FR only) |
S00312J |
S00312J |
S00312J |
S00312J |
|
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) |
S00205 |
S00205 |
S00205 |
S00205 |
|
Calibration of an additional temperature value (not subject to discount) |
S00215 |
S00215 |
S00215 |
S00215 |
|
Calibration of one freely selectable temperature and humidity value (requires Option K7) (excluding travel costs, not subject to discount, GER, AT, FR only) |
S00207 |
S00207 |
S00207 |
S00207 |
|
Calibration of an additional temperature and humidity value (requires option K7) (not subject to discount) |
S00216 |
S00216 |
S00216 |
S00216 |
|
Calibration of one freely selectable temperature and humidity value including CO2 (excluding travel costs, not subject to discount, GER, AT, FR only) |
S00211 |
S00211 |
S00211 |
S00211 |
|
Calibration of an additional temperature and humidity value including CO2 (not subject to discount) |
S00217 |
S00217 |
S00217 |
S00217 |