Options / Accessories

for Compressor-cooled incubator

Ideal for ramp operation with rapid temperature changes during incubation, breeding or storage.

Option

Model sizes 110 110 eco 260 260 eco 450 450 eco 750 750 eco
Voltage 115 V, 50/60 Hz X2 X2 X2 X2
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of standard grids by reinforced grids K1 K1 K1 K1
Interior socket (can only be ordered with limited temperature range - max. +60 °C), ampacity 230V/2, 2A/500W, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 (requires option A8 against surcharge) R3 R3 R3 R3 R3 R3 R3 R3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0 F0 F0 F0 F0 F0 F0 F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1 F1 F1 F1 F1 F1 F1 F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3 F3 F3 F3 F3 F3
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) F7 F7 F7 F7 F7 F7 F7 F7
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA) Temperature controller actual value V3 V3 V3 V3 V3 V3 V3 V3
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6 V6 V6 V6 V6 V6 V6 V6
Fan speed monitoring with switching off the heating and with alarm in case of failure V4 V4 V4 V4 V4 V4 V4 V4
Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C D00130 D00130 D00130 D00130 D00130 D00130 D00130 D00130
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109 D00109 D00109 D00109 D00109 D00109 D00109 D00109
Door with lock (safety lock) Door with lock (safety lock) B6 B6 B6 B6 B6 B6 B6 B6
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6 H6 H6 H6 H6 H6 H6
Door-open-recognition (only for units with TwinDISPLAY) V5 V5 V5 V5 V5 V5 V5 V5
MobileALERT, notification by SMS in case of any error or alarm of the device (Requires option H6) C3 C3 C3 C3 C3 C3 C3 C3

Accessory

Model sizes 110 110 eco 260 260 eco 450 450 eco 750 750 eco
Stainless steel grids, electropolished Stainless steel grids, electropolished E20165 E20165 E28891 E28891 E20182 E20182 E20182 E20182
Reinforced stainless steel grid, electropolished, max. loading 60 kg; from size 450 with guide bars and fixing screws (only in connection with option K1). Please consider max. loading of chamber E29767 E29767 E29766 E29766 B32190 B32190 B32190 B32190
Perforated stainless steel shelf Perforated stainless steel shelf B00325 B00325 B29725 B29725 B00328 B00328 B00328 B00328
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1. Please consider max. loading of chamber B32191 B32191 B32191 B32191
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02073 E02073 E29726 E29726 E02075 E02075 E02075 E02075
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763 B32763 B32763
Max. loading per slide-in drip tray (kg) 3 3 4 4 8 8 8 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04359 B04359 B29722 B29722 B04362 B04362 B04362 B04362
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055 B34055 B34055 B34055
Max. loading per bottom drip tray (kg) 3 3 4 4 8 8 8 8
USB-Ethernet adapter E06192 E06192 E06192 E06192 E06192 E06192 E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189 E06189 E06189 E06189 E06189 E06189 E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170 B33170 B33170 B33170 B33170 B33170 B33170 B33170
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1 FDAQ1
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence (only for units with TwinDISPLAY) FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2 FDAQ2
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696 E39696 E39696 E39696 E39696 E39696 E39696 E39696
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) E39697 E39697 E39697 E39697 E39697 E39697 E39697 E39697
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124 D00124 D00124 D00124 D00124 D00124 D00124
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127 D00127 D00127 D00127 D00127 D00127 D00127 D00127
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100 DLQ100
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A DLQ100A
Individual on-site Performance Qualification (PQ) DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200 DLQ200
Maintenance ICP/ ICPeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00315 S00315 S00315 S00315 S00315 S00315 S00315 S00315
Maintenance contract ICP/ ICPeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00315J S00315J S00315J S00315J S00315J S00315J S00315J S00315J
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, FR only) S00205 S00205 S00205 S00205 S00205 S00205 S00205 S00205
Calibration of an additional temperature value (not subject to discount) S00215 S00215 S00215 S00215 S00215 S00215 S00215 S00215