Options / Accessories

for Compressor-cooled incubator ICP110

Option

Option Order No.
Voltage 115 V, 50/60 Hz X2
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1
Entry port (silicone), 40 mm clear diameter, for introducing connections, moisture tight, can be closed by silicone stopper, at the back (please, state location) F7
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA) Temperature controller actual value V3
4 – 20 mA current loop interface (-20 to +70°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
Fan speed monitoring with switching off the heating and with alarm in case of failure V4
Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C Works calibration certificate for 3 temperatures: 0°C, +37°C, +60°C. Standard works calibration certificate (measuring point chamber centre) at +10°C and +37°C D00130
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109
Door with lock (safety lock) Door with lock (safety lock) B6
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Door-open-recognition (only for units with TwinDISPLAY) V5
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3

Accessory

Accessory Order No.
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E20165
Reinforced stainless steel grid, max. loading 60 kg, from size 450 with guide bars and fixing screws and only in connection with option K1 E29767
Perforated stainless steel shelf Perforated stainless steel shelf B00325
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E02073
Max. loading per slide-in drip tray (kg) 3
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B04359
Max. loading per bottom drip tray (kg) 3
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
DAkkS calibration for one free-selectable temperature value according to method C (DKD-R 5-7) E39696
DAkkS calibration for further temperature values according to method C (DKD-R 5-7) E39697
Individual on-site Performance Qualification (PQ) DLQ200
Maintenance contract ICP/ ICPeco - carrying out and documentation according to Memmert maintenance plan, minimum duration 3 years (excluding travel costs, not subject to discount, GER, AT, FR only) S00315J
Maintenance ICP/ ICPeco - carrying out and documentation according to Memmert maintenance plan (excluding travel costs, not subject to discount, GER, AT, FR only) S00315
Calibration of an additional temperature value (not subject to discount) S00215
On-site IQ/OQ for a freely selectable temperature value, including temperature distribution survey for 27 measuring points to DIN 12880: 2007-05 (excluding travel costs, not subject to discount, GER, AT, FR only) DLQ100
Extension of DLQ100 by an additional freely selectable temperature value (not subject to discount) DLQ100A
Calibration of one freely selectable temperature value (excluding travel costs, not subject to discount, GER, AT, CH, FR only) S00205