Voltage 115 V, 50/60 Hz (no extra cost) |
X2 |
X2 |
X2 |
X2 |
X2 |
|
|
|
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids (standard with 1060) |
|
|
|
K1 |
|
|
|
|
Light module cold white 6,500 K: LED light strips arranged on the side walls of the interior,10 for model 110, 14 for model 260/400/750,programme controlled dimming from 0 to 100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7) |
T7 |
T7 |
T7 |
T7 |
|
|
|
|
Light module cold white 6,500K + warm white 2,700K: LED light strips - 10 stripes for model 110, 14 for model 260/400/750 (6 resp. 8 alternating coldwhite light strips and 4 resp. 6 warm white light strips) on the side walls of the interior, programme-controlled dimming from 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7) |
T8 |
T8 |
T8 |
T8 |
|
|
|
|
Light module warm white 2,700 K: light strips arranged on the side walls of the interior, 10 strips for model 110, 14 for model 260/400/750, programme-controlled dimming rom 0 to100% (in 1 % steps), ramp programming in combination with temperature and humidity (not in combination with F6, F7) |
T9 |
T9 |
T9 |
T9 |
|
|
|
|
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 |
R3 |
R3 |
R3 |
R3 |
R3 |
|
|
|
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 |
R4 |
R4 |
R4 |
R4 |
R4 |
|
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre |
F0 |
F0 |
F0 |
F0 |
F0 |
|
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top |
F1 |
F1 |
F1 |
F1 |
F1 |
|
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre |
F2 |
F2 |
F2 |
F2 |
F2 |
|
|
|
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top |
F3 |
F3 |
F3 |
F3 |
F3 |
|
|
|
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
F4 |
|
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
F5 |
|
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location; not in combination with T7, T8, T9) – rear |
F6 |
F6 |
F6 |
F6 |
F6 |
|
|
|
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please, state location; not in combination with T7, T8, T9) |
F7 |
F7 |
F7 |
F7 |
F7 |
|
|
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA)
Temperature controller, actual value |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
V3 |
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA)
Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
V6 |
|
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA)
Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) |
V7 |
V7 |
V7 |
V7 |
V7 |
V7 |
V7 |
|
Works calibration certificate for one (freely selectable) temperature and humidity value |
D00105 |
D00105 |
D00105 |
D00105 |
D00105 |
D00105 |
D00105 |
|
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. |
C9 |
C9 |
C9 |
C9 |
C9 |
C9 |
C9 |
|
Door with lock (safety lock) |
B6 |
B6 |
B6 |
B6 |
B6 |
|
|
|
Door with lock (safety lock), two locks (one each door) |
|
|
|
|
|
B62 |
|
|
Door with lock (safety lock), three locks (one each door) |
|
|
|
|
|
|
B63 |
|
Door hinged on the left |
B8 |
B8 |
B8 |
|
|
|
|
|
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
H6 |
|
Process-dependent programmable door lock (only for units with TwinDISPLAY) |
D4 |
D4 |
D4 |
D4 |
D4 |
|
|
|
Process-dependent programmable door lock, two interlocking systems (one each other) |
|
|
|
|
|
D42 |
|
|
Process-dependent programmable door lock, three interlocking systems (one each other) |
|
|
|
|
|
|
D43 |
|
Door-open-recognition (only for units with TwinDISPLAY) |
V5 |
V5 |
V5 |
V5 |
V5 |
|
|
|
Door-open-recognition, two (one each door) |
|
|
|
|
|
V52 |
|
|
Door-open-recognition, three (one each door) |
|
|
|
|
|
|
V53 |
|
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
C3 |
|
Castor frame (2-part), height 140 mm |
R9 |
R9 |
|
|
|
|
|