Options / Accessories

for Constant climate chamber HPP1060

Our constant climate chamber is tailored to environmental simulation, material testing and stability testing in accordance with the ICH guidelines.

Option

Option Order No.
Voltage 115 V, 50/60 Hz (no extra cost) X2
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 R4
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre/centre F0
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position left centre top F1
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre/centre F2
Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper, standard position right centre top F3
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - left F4
Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, moisture tight, can be closed by flap and silicone stopper (please, state location) - right F5
Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location; not in combination with T7, T8, T9) – rear Entry port, 23 mm clear diameter, moisture tight, can be closed by flap and silicone stopper, in special positions (please, state location; not in combination with T7, T8, T9) – rear F6
Entry port (silicone), 40 mm clear diameter, moisture tight, can be closed by silicone stopper, at the back (please, state location; not in combination with T7, T8, T9) F7
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature controller, actual value V3
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 3 TwinDISPLAY) V6
4 – 20 mA current loop interface (-10 to +80°C corresponds to 4 to 20 mA) Humidity controller, actual value (0 – 100 % rh corresponds to 4 – 20 mA) V7
Works calibration certificate for one (freely selectable) temperature and humidity value D00105
Compressed air dehumidification (efficient dehumidification of the interior by means of compressed air). Standard works calibration certificate (measuring point chamber centre) at +10 °C with 10 % rh. C9
Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 Door with lock (safety lock), Standard with SN/SF and SNplus/SFplus 450 and 750 B6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) Potential-free contact (24 V/2 A) with socket to NAMUR NE 28 for external monitoring (indicates when setpoint is reached) H5
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6
Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts Potential-free contact (24 V/2 A) with socket to NAMUR NE 28, for signal generation, controlled by programme segment, for free-selectable functions to be activated (e.g. activation of audible and visual signals, exhaust motors, fans, stirrers, etc. Only for units with TwinDISPLAY; max 2 contacts on 1-phase appliances; max 4 contacts on 3-phase appliances, 2 contacts H72
Process-dependent programmable door lock (only for units with TwinDISPLAY) D4
Door-open-recognition (only for units with TwinDISPLAY) V5
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) max. 3 sensors H4
Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. Additional Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the display, recorded in the integral ring store, and can be documented via the AtmoCONTROL software. H8
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3

Accessory

Accessory Order No.
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) B41251
Reinforced stainless steel grid, electropolished, max. loading 60 kg (model 750 with guide bars and fixing screws and only in connection with option K1) B32550
Perforated stainless steel shelves B32549
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B32599
Max. loading per slide-in drip tray (kg) 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B29769
Max. loading per bottom drip tray (kg) 8
Central water supply with filter cartridges for connection to the domestic water supply. Product information on demand. ZWVR6
Central water supply without filter cartridges for connection to the domestic water supply (only for demineralised water with a conductivity of 5 to 10 μS/cm and a pH value between 5 and 7). Product information on demand ZWVR7
Guarantee extension by 1 year GA4Q5
USB-Ethernet adapter E06192
Ethernet connection cable 5 m for computer interface E06189
USB User-ID stick (with User-ID licence): Oven-linked authorisation licence (User-ID-programme) on Memory-stick, prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number (only for units with TwinDISPLAY) B33170
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29743
Integration of one additional unit (up to max. 31 units) into an already existent FDA-software licence FDAQ2
FDA conforming software AtmoCONTROL (FDA edition). Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Base licence for the control of one unit. Respective IQ/OQ documents available in German and English language (without surcharge) FDAQ1
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, incl. temperature distribution survey at Memmert for 27 measuring points (26 measuring points on model HPP1400) to DIN 12880:2007-05, PQ check list as support for validation by customer (models HPP and ICH). D00136
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124
IQ/OQ document with device-specific works test data for one free-selectable temperature and humidity value, and measuring of light intensity, incl. temperature distribution survey at Memmert for 27 measuring points to DIN 12880:2007-05, PQ check list as support for validation by customer. Price for validation at customer site on demand (GER, AT, CH only) D00137
External measuring instrument with sensors with additional measuring head for temperature and humidity measurement. Product information on demand (models HPP, ICH, ICH L, ICH C, IPPplus and ICOmed) B04714