Options / Accessories

for Cooled storage incubator

Sample breeding and storage in microbiology, food, cosmetics or pharmaceutics: The cooled storage incubator with Peltier elements lowers operating costs as well as CO2 emissions.

Option

Model sizes 260 750
Voltage 115 V, 50/60 Hz (no extra cost) X2 X2
Chamber modification for the application of reinforced perforated stainless steel shelves or stainless steel grids (bearing rails mounted in the working chamber) – includes replacement of 2 standard grids by 2 reinforced grids K1
Interior socket, ampacity 230 V/2.2 A, can be switched off with the On/Off switch, cannot be switched individually, moisture tight IP68 R3 R3
Interior socket (can only be ordered with limited temperature range - max. +70 °C). ampacity 230 V/2.2 A, can be switched on/off via tumbler switch in control panel, moisture tight IP68 R4 R4
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre/centre F0 F0
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position left centre top F1 F1
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre/centre F2 F2
Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top Entry port, 23 mm clear diameter, for introducing connections at the side, can be closed by flap, position right centre top F3 F3
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - left F4 F4
Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right Entry port, 23 mm clear diameter for introducing connections at the side, can be closed by flap in special positions (please, state location) - right F5 F5
Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear Entry port, 23 mm clear diameter for introducing connections, can be closed by flap in special positions (please, state location) - rear F6 F6
Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 14 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) D6 D6
Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) Entry port, 38 mm clear diameter, can be closed by flap, in special positions at the back (please, state location) F7 F7
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA) Temperature controller actual value V3 V3
4 – 20 mA current loop interface (0 to +70°C corresponds to 4 – 20 mA) Temperature of a Pt100 sensor positioned flexibly in chamber for external temperature monitoring (max. 1 SingleDISPLAY) V6 V6
Works calibration certificate for one (freely selectable) temperature value according to customer specification D00109 D00109
Door with lock (safety lock) Door with lock (safety lock) B6 B6
Door hinged on the left B8
Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) Potential-free contact for combination error message (e.g. supply failure, sensor fault, fuse) H6 H6
Door-open-recognition (only for units with TwinDISPLAY) V5 V5
MobileALERT, notification by SMS in case of any error or alarm of the device. Requires option H6 “floating contact for alarm” C3 C3
Castor frame (2-part), height 140 mm Castor frame (2-part), height 140 mm R9

Accessory

Model sizes 260 750
Stainless steel grids, electropolished (standard equipment) Stainless steel grids, electropolished (standard equipment) E28891 E20182
Reinforced stainless steel grid, max. loading 60 kg (size 750 with guide bars and fixing screws and only in connection with option K1) E29766 B32190
Perforated stainless steel shelf Perforated stainless steel shelf B29725 B00328
Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 Reinforced perforated stainless steel shelves, max. loading 60 kg, with guide bars and fixing screws and only in connection with option K1 B32191
Stainless steel slide-in drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 E29726 E02075
Stainless steel slide-in drip tray, 15 mm rim, with guide bars and fixing screws (may affect the temperature distribution) - can be used only in connection with option K1 B32763
Max. loading per slide-in drip tray (kg) 4 8
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - cannot be used in connection with option K1 B29722 B04362
Stainless steel bottom drip tray, 15 mm rim (may affect the temperature distribution) - can be used only in connection with option K1 B34055
Max. loading per bottom drip tray (kg) 4 8
Guarantee extension by 1 year GA2Q5 GA2Q5
USB-Ethernet adapter E06192 E06192
Ethernet connection cable 5 m for computer interface E06189 E06189
USB stick with documentation software AtmoCONTROL and operation manual for products with SingleDISPLAY (the standard equipment of appliances with TwinDISPLAY includes one USB stick with AtmoCONTROL) B33172 B33172
Set of height adjustable feet (4 pcs). Standard on models ICOmed B29768
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), with air slots – technical clarification required B29738 B29742
Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required Flush-fit unit (stainless steel frame covering gap between oven and wall opening), without air slots – technical clarification required B29739 B29743
Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) Subframe, adjustable in height (size 30 to 75: height 600 mm, size 110 to 450: height 500 mm) B29751
Subframe, adjustable in height (height 130 mm, for example for units with fresh-air filter) B33664
IQ/OQ document with works test data for chamber, incl. temperature distribution survey for one free-selectable temperature value. 9 measuring points (size 30), 27 measuring points (sizes 55 - 1060) to DIN 12880:2007-05 (further temperature values on demand), PQ check list as support for validation by customer D00127 D00127
IQ document with device-specific works test data, OQ/PQ check list as support for validation by customer D00124 D00124