Options / Accessories

for Cooled vacuum oven

For gentle drying of bacteria and starter cultures or simulation of intercontinental flights.

Option

Model sizes 29 49
Works calibration certificate for one (freely selectable) temperature and pressure value (per thermoshelf) according to customer specification D00116 D00116
Extended temperature-range (0°C to +90°C) A8 A8
Works calibration certificate for 3 temperatures: +5°C, +30°C, +90°C at 20 mbar pressure D00133 D00133
RS232 interface instead of USB W6 W6
Computer interface RS485 (for networking a max. of 16 ovens) instead of RS232 V2 V2
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 H5
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 H6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) H7 H7

Accessory

Model sizes 29 49
IQ/OQ document with device-specific works test data for one free-selectable temperature and vacuum value, incl. temperature distribution survey at Memmert for 5 measuring points per thermoshelf to DIN 12880:2007-05. PQ check list as support for validation by customer valid for one thermoshelf; dito further thermoshelves, price on demand. D00117
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz PMP 29 PMP 49
Noise-insulated vacuum pump module without pump (exterior dimensions and -material No. s. vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM29 PM49
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm, see "further data" and sketch of oven dimensions) E02030 E02031
Removable bottom drip tray – stainless steel material 1.4404 (ASTM 316 L) E04256 E04257
Signal cable (3 m) for optimising pump performance by demand-controlled activation of purge of Memmert pump B04027 B04027
Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) B04026 B04026
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years B04133
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 60 Nl./min = 3,6 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 60 Nl./min = 3,6 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years B04134
Guarantee extension by 1 year GA2Q5 GA2Q5
USB connection cable for computer interface E03643
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps E05284
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) E04004
Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number E04159
Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Not applicable for UFP800DW E05019
Integration of additional units (up to max.16 units) into an already existent FDA-software licence. Not applicable for UFP800DW FDAQ4
IQ check list with works test data for chamber as support for validation by customer D00103
OQ check list with works test data for one free-selectable temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer D00104