Options / Accessories

for Cooled vacuum oven VO200cool

Option

Option Order No.
Extended temperature-range (0°C to +90°C) A8
Works calibration certificate for 3 temperatures: +5°C, +30°C, +90°C at 20 mbar pressure D00133
RS232 interface instead of USB W6
Computer interface RS485 (for networking a max. of 16 ovens) instead of RS232 V2
Door with lock (safety lock, not available for VO, VOcool, TTC/CTC) B6
Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) Flexible Pt100 for positioning in chamber or in load with socket, 4-pin, according to NAMUR NE 28, for external temperature recording (load temperature) H4
Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) Flexible Pt100 temperature sensor, positioned flexibly in chamber or load, for local temperature measurement (up to 3 additional sensors are possible). The measured temperature can, if required, be indicated on the multifunction display, recorded in the integral ring store, and can be documented via the “Celsius” software or on an attached printer. (not available for VO, VOcool, TTC and CTC) H8
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for external monitoring (indicates when setpoint is reached); VO only in combination with option T5 H5
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28 for combination error message (e.g. supply failure, sensor fault, fuse); VO only in combination with option T5 H6
Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) Potential-free contact (24 V/2 A) with socket, according to NAMUR NE 28, triple, for signal generation, controlled by programme segment for a total of 3 freely selected functions to be activated (e.g. acoustic and visual signals, exhaust motors, fans, stirrers etc.) H7

Accessory

Accessory Order No.
Removable bottom drip tray – stainless steel material 1.4404 (ASTM 316 L) E04256
Noise-insulated vacuum pump module without pump (exterior dimensions and material No. see vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven Noise-insulated vacuum pump module without pump (exterior dimensions and material No. see vacuum oven) with antivibration metal plate at the bottom to accommodate the vacuum pump, incl. full-sight glass door. Socket, signal cable and connecting hose to the vacuum oven PM 200
Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) Noise-insulated vacuum pump module, as above, however with built-in pump, 230 V, 50/60 Hz (pump B04133 for VO 200 and pump B04134 for VO 400 and 500) PMP 200
Signal cable (3 m) for optimising pump performance by demand-controlled activation of purge of Memmert pump B04027
Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) Vacuum connecting hose (3 m) from oven to Memmert pump incl. optimised connection accessories (partially stainless steel) B04026
Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years Chemically resistant vacuum pump with PTFE double diaphragm, pump capacity at atm. pressures: approx. 34 Nl./min = 2,04 m³/h and autom. purge control from vacuum oven. Order No. B04027 and B04026 necessary. 230 V, 50/60 Hz. Max. guarantee period 2 years B04133
Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463 Subframe, tubular steel, black enamelled (for stacking unit consisting of vacuum oven and pump module, total height: 1650 mm) Width/ Height/ Depth: model 200: 529/450/383, model 400: 529/290/463 E02030
Guarantee extension by 1 year (VOcool only) GA2Q5
USB connection cable for computer interface E03643
Temperature profile write/read unit for programming via PC, for writing to and reading from the chip card, up to 40 ramps E05284
Additional chip card, blank, formatted (32 kB MEMoryCard XL for a maximum of 40 ramps) E04004
Oven-linked authorisation card (User-ID-Card) prevents undesired manipulation by unauthorised third parties. When reordering please specify serial number E04159
Software conforming to FDA ”Celsius FDA Edition“ for up to 16 units. Meets the requirements for the use of electronically stored data sets and electronic signatures as laid down in Regulation 21 CFR Part 11 of the US Food and Drug Administration (FDA). Not applicable for UFP800DW E05019
Integration of additional units (up to max.16 units) into an already existent FDA-software licence. Not applicable for UFP800DW FDAQ4
IQ check list with works test data for chamber as support for validation by customer D00103
OQ check list with works test data for one free-selectable temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer D00104
OQ check list with works test data for one free-selectable temperature and vacuum value incl. temperature distribution survey for 5 measuring points to DIN 12880:2007-05 as support for validation by customer (VO, VOcool only) valid for one thermoshelf, dito for further thermoshelves VO: EUR 340,– each D00117
OQ check list with works test data for one free-selectable humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models HCP and CTC) D00104
OQ check list with works test data for one free-selectable CO2, humidity and temperature value incl. temperature distribution survey for 27 measuring points to DIN 12880:2007-05 as support for validation by customer (models INCOmed) D00104
External measuring instrument with sensors for daylight and UV-light, with additional measuring head for temperature and humidity. Product information on demand (models HCP and CTC) B04714